This command can only be performed in AUX user interface view.
By default, the mode is set to none.
Example
# Set mark parity on the AUX (Console) port.
[Quidway-ui-aux0] parity mark

1.1.16 quit

Syntax
quit
View
Any view
Parameter
none
Description
Using quit command, you can return to the lower level view from the current view. If
the current view is user view, you can quit the system.
There are three levels of views, which are listed from low to high as follows:
User view
System view
VLAN view, Ethernet port view, and so on.
For the related commands, see return, system-view.
Example
# Return to user view from system view.
[Quidway] quit
<Quidway>

1.1.17 return

Syntax
return