Stp Timeout-Factor; Stp Timer Forward-Delay - Huawei Quidway S2000 Series Command Manual

Table of Contents

Advertisement

Command Manual - STP
Quidway S2000 Series Ethernet Switches

1.1.16 stp timeout-factor

Syntax
stp timeout-factor number
undo stp timeout-factor
View
System view
Parameter
number: Specifies the multiple of hello time, ranging from 3 to 7.
Description
Using stp timeout-factor command, you can configure multiple of hello time for the
switch. Using undo stp timeout-factor command, you can restore the default multiple
value.
By default, the multiple is 3.
The Ethernet switch transmits RSTP packets every hello time. Generally, if the switch
doesn't receive the RSTP packets from the upstream switch for 3 times of hello time,
the switch will decide the upstream switch is dead and will recalculate the topology of
the network. Then in steady network, the recalculation may be caused when the
upstream is busy. In this case, user can redefine the timeout interval to a longer time
by define the multiple of hello time. The stp timeout-factor command can be used to
modify the value of multiple. It is recommended to set 5, 6 or 7 as the value of multiple
in the steady network.
Example
# Set the multiple value of hello time to 7.
[Quidway] stp timeout-factor 7

1.1.17 stp timer forward-delay

Syntax
stp timer forward-delay centiseconds
undo stp timer forward-delay
View
System view
Chapter 1 RSTP Configuration Commands
1-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents