Command Manual - Integrated Management
Quidway S2000 Series Ethernet Switches
The member device within cluster will access FTP server via administrator device.
Configure the IP address of FTP server for the cluster, then the member devices of the
cluster can access the server via the administrator device.
Example
# Configure the IP address of FTP server for the cluster on the administrator device.
[Huawei_0.Quidway-cluster] ftp-server 1.0.0.9

1.3.13 holdtime

Syntax
holdtime seconds
undo holdtime
View
Cluster view
Parameter
seconds: Valid holdtime in seconds, ranging from 1 to 255. By default, the valid
holdtime is 60 seconds.
Description
Using holdtime command, you can configure the valid holdtime of a switch. Using
undo holdtime command, you can restore the default value of holdtime . After missing
3 times of handshake, if the switch still cannot receive any information of the peer
device during holdtime, it will set the state of peer device to "down". When the
communication resumes, the relevant member device will be re-added to the cluster
(automatically). If the downtime does not go beyond the valid holdtime specified by the
user, the member device will stays in the normal state and need not be added again.
The commands can only be executed on the administrator device, which will advertise
the cluster timer value to the member devices.
Example
# Set the cluster holdtime as 50 seconds.
[Huawei_0.Quidway-cluster] holdtime 50