Command Manual - Integrated Management
Quidway S2000 Series Ethernet Switches
View
System view
Parameter
hop-value: Indicate the maximum hops that the device collected can be away from the
topology collecting device, ranging from 1 to 16. By default, the value is 3.
Description
Using ntdp hop command, you can configure a limit to the hops for topology collection
to collect the topology information of the devices among determined range, so that
infinitive collection can be avoided. Using undo ntdp hop command, you can restore
the default value. The limit is performed through controlling permitted hops from the
originating of collection. For example, if you set a limit of 2 to the hop number, only the
switches 2 hops away from the first switch transmitting the topology collection request
will be collected.
This command is only effective on the topology-collecting device. The broader
collection scope requires more memory of the topology-collecting device.
Example
# Set a limit of 5 hops for topology collection.
[Quidway] ntdp hop 5

1.2.6 ntdp timer

Syntax
ntdp timer interval-in-mins
undo ntdp timer
View
System view
Parameter
Interval-in-mins: The interval of collecting topology information periodically, ranging
from 0 to 65535 in minutes. 0 indicates that no regular topology collection will be
performed.
Chapter 1 HGMP V2 Configuration Commands