Deleting Devices - Eaton i-on series Engineering Manual

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

i-on Range
b).
Press SELECT.
The blue LED 1 glows. The WAM is in menu 1.
2.
Press SET.
If any blue LEDs flash then those channels are already
in use.
3.
Activate tampers on all transmitters that the WAM needs
to learn.
Each time the WAM learns a detector a blue LED glows
to show the channel that detector is using.
4.
Leave programming mode as follows:
a)
Leave menu 1 by pressing ESC.
The blue LED 1 glows steadily.
b)
Press ESC again.
The blue LED 1 goes dark. The sounder gives a regular
beeping tone to remind you to replace the lid.
c)
Close the lid tamper.
After a few seconds the WAM bleeps twice and the red
Trouble LED goes dark.
NOTE: You must leave programming mode in order to save
the changes you have made.
5.
Check that the control unit can receive signals from the
transmitters learned by the WAM.

Deleting Devices

If you need to delete detectors from a WAM, perhaps in order to move them from one
repeater to another, then:
1.
Enter programming mode as follows:
a)
Open the tamper switch.
The Red Trouble LED glows.
b).
Press SELECT.
The blue LED 1 glows.
Appendix III
Page 147

Advertisement

Table of Contents
loading