Installer Menu Options
Instant Set
Silent Set
Lock Set
Page 78
The system sets immediately and without any setting
tone. The keypad(s) give confirmation tone when the
system is set.
Note: This option does not comply with BS8243:2010.
The system sets after the time programmed in the
Entry/Exit Time menu but does not give any exit tones
over the loudspeaker or keypad. When the system
sets the keypad (but not the loudspeaker) gives a
double beep confirmation tone.
(The keypad(s) give a double beep confirmation tone
at the end of all setting modes.)
The control unit logs the start of silent set.
On entry both keypads and loudspeakers give entry
tones.
Note: This option does not comply with BS8243:2010.
Lock Set exit mode affects both setting and unsetting.
To use Lock Set exit mode you must provide a Lock
Set zone (see page 49) connected to a suitable lock
on the final exit door, and you must also provide a
Final Exit zone (see page 46) connected to the final
exit door.
Eaton's Security Business recommends that you do
not use Lock Set within a Part Set. The results may
not function as described below.
Setting: To set the system a user must first start the
setting sequence by using an access code or prox tag
at a keypad, or by remote control.
After verifying the access code or prox the control unit
starts the exit tone and logs the start of lock set.
(During exit the control unit gives an interrupted exit
tone if the final exit zone is active.)
The exit tone sounds until the user a) closes the Final
Exit door and then b) operates the lock connected to
the Lock Set zone, activating the zone.
When the user activates the Lock Set zone the control
unit sets the system when the Settle Time expires.
The control unit also starts the settle time (if specified,
see page 80) at the end of which any PIR zones
become armed.
In addition, the control unit:
Converts the Final Exit zone in the set partition to
a Normal Alarm zone.
Logs the activation of the Lock Set zone.
Unsetting: If the system or partition is set then when
a user de-activates the Lock Set zone, the control
unit: