Eaton i-on series Engineering Manual page 119

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

i-on Range
3.
The control unit delays reporting/logging either mains loss, or exiting Installer Menu
with mains loss, by 15-18 min (chosen randomly).
4.
The control unit communicates Jamming, Supervision when the system is unset.
5.
The control unit communicates Mains Fail depending on the time programmed in
System Options – Mains Fail Delay (see page 103 for a detailed description).
6.
If there is no channel allocated for Tamper events then the control unit may report
tampers as Burglar Alarms to ensure that the ARC is notified.
CID/SIA Events
(This menu appears only if you select "Contact ID" or any of the SIA versions in
Communications - Report Types. See Appendix I for a description of the CID and SIA
formats.)
To make programming easier, the control unit groups CID/SIA telegrams together into
Report Groups. Tables 3 and 4 list the CID/SIA codes included in each report group. When
you enable a Report Group, then you are enabling the control unit to send any of the
telegrams in that group.
CID/SIA alarm transmissions will take considerably more telephone time than Scancom
Fast Format since the system transmits extended alarm data to the ARC.
Note: The control unit delays reporting/logging either A/C mains loss, or leaving Installer
Menu with A/C mains loss, by 15-22 minutes (chosen randomly). The control unit
delays reporting/logging either mains restore, or leaving Installer Menu with mains
restored, by 60-90 sec (chosen randomly).
CID
Includes:
Code
110
Fire and fire restore
120
Zone HUA (PA) and restore
Silent HUA (PA) and restore
Keypad HUA (PA), Keypad HUA (PA) restore
RF HUA (PA), RF HUA (PA) restore
Radio keypad HUA (PA), radio keypad HUA (PA) restore
121
Duress code alarm
129
HUA (PA) confirm
130
Burg and Burg restore
137
Panel Lid tamper and restore
Keypad tamper and restore
Detector tamper and restore
Bell tamper and restore
Radio keypad tamper and restore
External siren tamper and restore
WAM tamper and restore
Missing bus device and restore
Tamper bus device and restore
139
Alarm confirmation
150
Technical alarm and restore
300
Fail and restore for: Aux 12V, Aux 14.4V, Bell 12V, Bus
12V, System 12V
Table 3. CID Report Groups
Installer Menu Options
CID Report Group
Fire Alarm
Hold Up Alarm
Hold Up Alarm
Hold Up Alarms
Burglar Alarm
Tampers
Burglar Alarm
Technical Alarm
Faults
Page 109