Eaton i-on series Engineering Manual page 60

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

Installer Menu Options
One partition only
01
HUA
02
Fire
04
24 Hr
07
Technical
10
Tamper
11
External PSU AC fail
12
External PSU Battery fault
13
External PSU Low Volts
14
External PSU Fault
External Warning Device
15
Fault
16
Hold Up Device Fault
Note: If you assign a zone to more than one partition then that zone will only be set when
all the partitions it belongs to are set.
When delivered from the factory, or if you restore the control unit to factory settings, then
all zones default to type Not Used (NU). When you assign a zone to a type other than NU
the control unit initially assigns the zone to partition 1.
Once you have entered the Partitions menu, press  or  to scroll through the list of
partitions followed by  or  to assign/de-assign the zone to each partition as necessary.
If you wish to assign/de-assign the zones to many partitions then (for zones types that
allow this) you can use the "All Partitions" option (in between the first and last partitions on
the menu) to either assign or de-assign the zone to all partitions in one go, as follows:
Press  or  to show "All Partitions" on the bottom line of the display.
1.
Press  or  to change the last word on the bottom right of the display to:
2.
"Yes" to assign the zone to every partition.
"No" to de-assign the zone from every partition.
Press  or  to scroll through the partition list and change the assignment of the
3.
zone as necessary.
Note that if you de-assign a zone from every partition and then try to leave the menu by
pressing  the control unit will display a warning and return you to the Partitions menu.
Any zone that is in use (has a type other than "NU") must be assigned to at least one
partition.
Zone Attributes
Note: This menu does not appear if a zone has the type "Not Used", "HUA", "Fire", or
"Keyswitch Momentary".
You can assign more than one attribute to a zone. Some attributes are not available for
certain zone types. In addition, some attributes may be unavailable for radio zones. The
display shows only the available attributes for the zone type you select.
To enable an attribute for a zone press  or  until the bottom line of the display shows
"Yes" at the right hand end.
Page 50
Any partition
03 Normal Alarm
05 Final Exit
06 Entry Route
08 Key Switch Momentary
09 Key Switch Latched
17 Log Only
18 Exit Terminate
21 Lock Set
24 Tamper Return
i-on Range

Advertisement

Table of Contents
loading