Installer Menu Options
than the Mains Fail Delay period the control unit will activate any AC Fail outputs and
report a mains fail to the ARC. If the mains failures do not overlap, and are both
individually shorter than the Mains Fail Delay period then the control unit logs the events
and activates any General Fault outputs, but will not send a report to the ARC.
If the external PSU is allocated to a partition, and mains power at the external PSU is off
for longer than the Mains Fail Delay period, then the control unit's report to the ARC can
show that the partition experienced a mains fail. This report is additional to any report the
control unit might send concerning a mains fail at the control unit.
The control unit provides different methods of reporting to the ARC. For mains fail
reporting each method differs in the detail that it can send:
 SIA/CID reports can indicate mains failure in individual partitions.
 Fast Format reports cannot show details of mains failure in partitions, only mains
failure as a system-wide fault. This means that although the system can report that
a mains failure occurred, it cannot show whether the failure was in the control unit
or in an external PSU.
 Plug-by outputs cannot show details of individual partitions for a mains failure. Like
Fast Format, they can only report mains failure as a system event.

Battery 2

160
This option can enable or disable alert reporting on the second backup battery. The
options are:
Enabled
The control unit will start an alert if battery 2 is missing or low voltage.
Disabled
The control unit will ignore the presence or absence of battery 2.

Set Time and Date

This option lets you set the control unit's internal clock to the correct time and date. You
will have to re-program the date and time if the control unit loses power for an extended
time and the battery is exhausted.
Note: The internal clock adjusts itself for daylight saving in Spring and Autumn.

Panel Tamper Return

This option allows you to select either CC or FSL for the Tamper Return (TR) terminal on
the control unit PCB. By default the terminal is closed circuit. If you select FSL then you
should insert a 2k2 resistor in series with the tamper return wire from the sounder.

Communications

Note: If you have connected a plug-by communicator then use the Outputs - Plug-by
Outputs menu to program the plug-by pins to control the communicator.
The Communications option in the Installer Menu contains all the options needed to
program how the control unit will communicate alarms. The menu sub-options appear only
if a communications module is fitted (except for the i-on30EXD and i-on50EXD). Note that
the i-on16 uses the i-sd01 plug-on module. but not the i-sd02, i-dig02 or i-gsm02.
Within the Communications option, the main menu items deal with the following areas: