Log only zones can be allocated to one or more partitions, and can use the Chime
attribute.
Exit Terminate ET (18)
Use this zone type to terminate setting when the system or partition exit mode is "Exit
Terminate" (see page 77). This zone type is designed for a normally open
momentary switch. Note that this zone type is armed during the setting time, but
inactive both while the system is set, and while the system is unset. If you apply the
Chime attribute to this zone, then the system will give a chime tone when the zone is
activated both while the system is unset and while the system is set.
Note: Zone types 19 and 20 are not used.
Lock Set LS (21)
Use this zone type to complete setting when the system or partition exit mode is
"Lock Set" (see page 78). This zone type is designed for a normally open switch (one
that is open when the lock is locked). Note that
AND when the system is
A Lock Set zone can take the Inverted attribute.
Eaton's Security Business recommends that you do not use Lock Set with a Part Set.
The results may not function as described.
Note: Zone types 22 and 23 are not used.
Tamper Return TR (24)
30 40 50 160
Note: This zone type is also available on an i-on16 when fitted with a keypad with
zones.
This zone type makes it possible to wire a tamper return wire from an external
sounder to a zone connection point.
The control unit monitors a Tamper Return zone at all times. When triggered in the
unset condition, only internal sounders operate. When triggered in the set condition,
the alarm response determines whether external sounders, strobe and
communications also respond to the alarm.
You can assign the Soak Test, Part Set, Omitable and Force Set attribute to this
zone type.
Note that the type of zone wiring assigned to the connection point determines the length of
tamper return cable. For a single core of standard alarm cable:
CC wiring has a limit of 6m
FSL 2k2/4k7 or 4k7/4k7 will allow up to 50m. (Eaton's Security Business
recommends that you do not use any other resistor pair values.)
This zone type is not available for radio zones.
Partitions
30 40 50 160
Note: This menu does not appear if a zone has the type "Not Used".
In a partitioned system some zones can be assigned to several partitions and some to one
only. The table below shows you how zones of different types can be allocated to
partitions.
set.
Installer Menu Options
this zone type is armed during setting
Page 49