Resetting A System After An Alarm; Programming Backlight And Leds On Key-K01/Kp01/Kpz01 - Eaton i-on series Engineering Manual

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

i-on Range
Alternatively, if you press  when you first select a name to edit, then the existing text
shifts right one character and you can insert a new character in the empty space.
To move the cursor left or right press  or  respectively. To delete characters press
.
Note: If you wish to leave a name or text unchanged then press
name change screen and restores the name to its previous value.
Press
when you have finished entering text.

Resetting a System After an Alarm

If a system is programmed for Installer Reset after an alarm, then you will have to do one
of the following:
A) Use Anti-Code reset (see page 102).
B) Using a suitable communicator, trigger the Remote Reset input on the plug-by output
pins.
C) Attend the site and enter the Installer Menu access code from a keypad. (The system
must be completely unset before you can carry out an Installer Reset.) If necessary key
in a valid user code (see page 88 ). On a part setting system, or one where all
partitions are unset, this will take you into Installer Menu. Leave Installer Menu to reset
the system. In a partitioned system where one or more partitions are still set, the
system will simply reset. If a user code is required, then on entry of the code the
system resets, and the keypad displays the time and date.
Programming Backlight and LEDs on KEY-
K01/KP01/KPZ01
On the KEY-K01/KP0/KPZ01 keypads you can enable or disable the backlights and set
the function of the LEDs in the ABCD and navigation keys by entering a local keypad
programming mode (this replaces the use of jumpers on the keypad PCB in the i-kp01). It
is possible to enter keypad programming mode when the keypad is not connected to a
control unit, but simply powered by 12VDC connected to the keypad bus terminal (see the
installation guide for each keypad for details). If the keypad IS connected to a control unit
then make sure that the control unit is in Installer Menu before entering the keypad's local
programming mode.
Entering Local Programming Mode
1.
Apply 12Vdc to the keypad.
2.
Enter Installer Menu on the control unit, if the
keypad is connected to a system.
3.
Open the keypad tamper.
Press and hold down B and  together for at
4.
least two seconds.
The keypad is now in local programming mode,
the display shows the current status.
To Switch ABCD LEDs ON or OFF
1.
Enter local programming mode (see above).
Basic Programming Procedures
. The display leaves the
MENU
ABCD LEDs
MENU
ABCD LEDs
Page 19