Installer Menu Options
By pressing  the user can set the system if there are zones with
Yes
the Omit Allowed attribute active.
No
The user must go to the Omit Menu to set the system if a zone is
active.
User Code Required
Use this option to ensure that an installer or maintainer cannot gain access to program the
system unless a user is present:
Yes
After the installer/maintainer enters their access code, the system
asks for a user access code before allowing access to the Installer
Menu.
No
The installer/maintainer can enter the Installer Menu by simply
keying in their own code.
Note: If you select this value then the control unit no longer
complies with EN50131. This value complies with BS8243
only if the user has given written consent.
2 Way Replies
Use this option to decide whether the control unit can send status messages to the two-
way remote control unit (FOB-2W-4B).
2 Way Set Instant
Use this option the decide how the two-way remote control unit (FOB-2W-4B) sets the
system:
Yes
The partition sets instantly when the user operates the FOB-2W-4B.
No
The partition follows the setting mode programmed for it in
"Partitions" or "Setting Options" (see page 77).
Duress Enable
This option allows Master Users to create duress user types. A duress code can set and
unset the system in the same way as a Normal User. However each time the code is used
the control unit triggers a Duress output. In addition the control unit communicates Duress
as appropriate, and also a set or unset event.
Yes
Master Users can create Duress user types.
No
The Duress user type is not available to assign to users.

User Reset

This menu option determines under what circumstances a user or the installer can reset
the system after an alarm.
Zone Alarms
(Appears when System Options – Confirmation – Confirmation Mode is set to "Basic",
see page 89.)
The user can reset the system after an alarm triggered by a zone's
Yes
alarm circuit.
No
The installer must reset the system after an alarm triggered by a
zone's alarm circuit. See also "Remote Reset" on page 89.
Note: If a user unsets the system during an alarm, but before the Alarm Abort
period has expired, then they can reset the system (see page 100).