Appendix VII
Batt= Charger Rstr
Battery Load OK
Bell 12V Fail
Bell 12V Rstr
Bell Tamper
Bell Tamper Rstr
Burg Z== Alarm
Burg Z== Restore
Bus # Tamper
Bus # Tamper Rstr
Codes Defaulted
Comms 12V Fail
Comms 12V Restore
Configuration Fail
Defaults Loaded
Disabled ==
Disabled ==
Enabled ==
Enabled ==
Entry Stray Z==
Exp. == deleted
Expndr == added
Expndr == added
Expndr == found
Expndr == found
EXP-PSU A/C Fail Flt
EXP-PSU A/C Fail Rst
EXP-PSU Aux Fuse Flt'
EXP-PSU Aux Fuse Rst'
EXP-PSU Aux1 O/P Flt'
EXP-PSU Aux1 O/P Rst'
EXP-PSU Aux2 O/P Flt'
EXP-PSU Aux2 O/P Rst'
EXP-PSU Batt 1 Rstr'
EXP-PSU Batt 1 Rstr'
EXP-PSU Batt 2 Rstr'
EXP-PSU Batt 2 Rstr'
EXP-PSU Bus O/P Flt'
EXP-PSU Bus O/P Rst'
EXP-PSU Chargr 1 Flt'
EXP-PSU Chargr 1 Rst'
EXP-PSU Chargr 2 Flt'
EXP-PSU Chargr 2 Rst'
EXP-PSU Coms O/P Flt'
EXP-PSU Coms O/P Rst'
Page 156
Control unit battery charger
working again.
Control unit battery passed load
test.
12V DC supply to bell failed.
12V DC supply to bell restored.
External wired siren tamper.
External wired siren tamper
restored.
Burglar alarm on zone n.
Burglar alarm on zone n restored.
Bus n has been tampered (for
example wires cut or
disconnected)
Bus n has been restored.
All access codes were returned to
factory defaults.
DC power to comms module
failed.
DC power to comms module
restored.
The current configuration is not
compatible with the software
revision level of the control unit.
The control unit was returned to
factory defaults.
Expander/keypad disabled.
Expander/Keypad disabled.
Expander/Keypad enabled.
Expander/Keypad enabled.
Stray on entry alarm at zone n.
Expander n deleted from bus.
Wired expander n added to bus.
Radio expander n added to bus.
New wired expander n found on
bus.
New radio expander n found on
bus.
EXP-PSU AC mains fail.
EXP-PSU AC mains restored.
EXP-PSU Aux fuse failed.
EXP-PSU Aux fuse restored.
EXP-PSU auxilliary output 1 fault.
EXP-PSU auxilliary output 1 fault
restored.
EXP-PSU auxilliary output 2 fault.
EXP-PSU auxilliary output 2 fault
restored.
EXP-PSU battery 1 restored.
EXP-PSU battery 1 missing
restored.
EXP-PSU battery 2 restored.
EXP-PSU battery 2 missing
restored.
EXP-PSU bus dc power output
fault.
EXP-PSU bus dc power output
restored.
EXP-PSU battery 1 charger fault.
EXP-PSU battery 1 charger fault
restored.
EXP-PSU battery 2 charger fault.
EXP-PSU battery 2 charger fault
restored.
EXP-PSU plug by comms output
fault.
EXP-PSU plug by comms output
fault restored.
EXP-PSU Ex Keys Rstr'
EXP-PSU Load 1 Fail'
EXP-PSU Load 1 OK'
EXP-PSU Load 2 Fail'
EXP-PSU Load 2 OK'
EXP-PSU Low Batt 1'
EXP-PSU Low Batt 2'
EXP-PSU Low Voltage'
EXP-PSU Miss Batt 1'
EXP-PSU Miss Batt 2'
EXP-PSU Sys Volt Flt'
EXP-PSU Sys Volt Rst'
EXP-PSU Voltage OK'
Ext A/C Fail Z==
Ext A/C Rstr Z==
Ext Batt Fault Z==
Ext Batt Rstr Z==
Ext Low Volts Z==
Ext PSU Fault Z==
Ext PSU Rstr Z==
Ext Volts Rstr Z==
Ext WD Fault Z===
Ext WD Restr Z===
Fire == Alarm
Fire Reset
Fire Restore
Fire Restore
Fire Z== Alarm
Fire Z== Restore
GSM CME Info --
GSM CMS Info --
HU == Alarm
HUA Cnf RF HD U---
HUA Cnf RF MD U---
HUA Conf Bus# Tamp
HUA Conf HD ==
HUA Conf HD RK==
HUA Conf Panel Jam
HUA Conf Panel Lid
HUA Conf. ==
HUA Conf. ==ER
HUA Confirm
i-on Range
The system was restored after a
user keyed in the wrong code
more than four times in a row at a
keypad.
EXP-PSU battery 1 failed load
test.
EXP-PSU battery 1 passed load
test.
EXP-PSU battery 2 failed load
test.
EXP-PSU battery 2 passed load
test.
EXP-PSU battery 1 low.
EXP-PSU battery 2 low.
External PSU reports low voltage.
EXP-PSU battery 1 missing.
EXP-PSU battery 2 missing.
EXP-PSU system voltage fault.
EXP-PSU system voltage fault
restored.
External PSU reports voltage OK.
Zone n with type AC Fail activated.
Zone n with type AC Fail restored.
Zone n with type Batt Fault
activated.
Zone n with type Batt Fault
restored.
Zone n with type Low Volts
activated.
Zone n with type Fault activated.
Zone n with type Fault restored.
Zone n with type Low Volts
restored.
A warning device has reported a
fault through zone n.
The fault reported through zone nn
by a warning device has been
restored.
Fire alarm at keypad.
User reset system after fire alarm.
Fire alarm at keypad restored.
Fire alarm restored from radio
keypad.
Fire alarm on zone n.
Fire alarm on zone n restored.
The GSM plu-on module has a
problem.
The GSM plu-on module has a
problem.
Hold Up Alarm started from
keypad nn.
Hold Up Alarm confirmed by radio
HUD belonging to user nn.
Hold Up Alarm confirmed by radio
Man Down transmitter belonging
to user nn.
Hold Up Alarm by a bus tamper.
Hold Up Alarm confirmed on
keypad HUA keys.
Hold Up Alarm confirmed on radio
keypad HUA keys.
Hold up alarm confirmed by panel
jamming.
Hold Up Alarm confirmed by panel
lid tamper.
Hold Up Alarm confirmed by
tamper on expander n.
Hold Up Alarm has been
confirmed by a missing external
prox reader on keypad n.
Hold Up Alarm confirmed on
device...