Appendix Vii: Log Messages; Log Events - Eaton i-on series Engineering Manual

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

i-on Range
This Appendix gives short explanations of the messages that may be stored in the control
unit's log.
Please note that many of the messages refer to specific equipment items by the bus and
device number. Therefore, it is not possible to show in this list the exact log message that
you may be seeing on any given installation.
The list itself is sorted alphabetically by the text of the message. In the column "Event Log
Text" you will see "==" or sometimes "#". These characters stand in for the zone, user or
device number that the control unit has recorded for the event being logged. In the
"Description" column this is shown as "nn" or "n". In the first seven messages listed the
characters "$m" stand in for the type of communications module fitted.

Log Events

Event Log Text
$m Alarm Fail
$m Line Fault
$m Line Restore
$m Modem Fault
$m Modem Restore
$m SMS Fail
$m Speech Fail
24hr Z=== Alarm
24hr Z=== Restore
A/C Fail
A/C Fail Ptn ##
A/C Restore
A/C Rstr Ptn ##
Alarm Abort U--
Alarm Conf ==ER
Alarm Conf Websvr
Alarm Conf. ==
Alarm Conf. ==
Alarm Confirm
Alarm Confirm Aux
Alarm Confirm Bell
Alarm Confirm RK==
Alarm Confirm Z==
Alarm Test Call
Alarm Test Call
All Comms Pths Flt
All Comms Pths Rst
Alm Conf Bus# Tamp

Appendix VII: Log Messages

Description
Communicator failed to send
alarm.
Communications line failed.
Communications line restored.
Modem failed.
Modem restored.
SMS call failed to get to
destination.
Speech dialler failed to send
alarm.
24 hour alarm on zone n.
24 hour alarm on zone n restored.
AC mains failed and was
communicated.
A zone assigned to partition 1 with
type "AC Fail" was triggered.
AC mains was restored.
A zone assigned to partition 1 with
type "AC Fail" was restored.
Alarm aborted by user.
Alarm has been confirmed by a
missing external prox reader on
keypad nn.
An alarm was confirmed by a user
on the web browser interface
typing the password incorrectly
more than four times in a row,
Confirmed alarm with tamper on
keypad.
Confirmed alarm with tamper on
expander.
Confirmed alarm.
Confirmed alarm with tamper on
AUX tamper terminals
Confirmed alarm with tamper on
bell.
Confirmed alarm with tamper on
radio keypad.
Confirmed alarm on zone.
Periodic alarm test call made.
Manual alarm test call made.
All communications paths have a
fault.
All communications path faults
restored.
An alarm was confirmed by a bus
tamper.
Alm Conf Panel Jam
Alm Conf Panel Lid
Alm Confirm SRN==
Alm Confirm WAM==
AS defer U-- P#
ATE L.F. All
ATE L.F. Restore
ATE L.F. Single
Auto Part Set #
Auto Ptn # PtSet
Auto Ptn # Set
Auto Ptn # Unset
Auto System Set
Auto System Unset
Autoset defer U--
Autoset Fail
Autoset Fail P#
Aux Tamper
Aux Tamper Rstr
Aux. 14V4 Fail
Aux. 14V4 Restore
Auxiliary 12V Fail
Auxiliary 12V Rstr
Bad checksum
Batt = Fault Rst
Batt = Load Fail
Batt = Low/Missing
Batt Fault Restore
Batt= Charger Fail
Alarm confirmed by panel
jamming.
Confirmed alarm with tamper on
control unit lid.
Confirmed alarm with tamper on
radio siren n.
Confirmed alarm with tamper on
WAM n.
User nn defered calendar setting
on partition n.
All lines to alarm transmission
equipment failed.
Line to alarm transmission
equipment restored.
Alarm transmission equipment has
a single line fault.
The system was part set by
calendar setting.
Partition n was part set by
calendar setting.
Partition n set by calendar setting.
Partition n unset by calendar
setting.
The system was full set by
calendar setting.
The system was unset by calendar
setting.
User defered calendar setting of
system.
Calendar setting of system failed.
Calendar setting of partition failed.
Aux Tamper terminals on main
pcb open circuit (i-on160 only)
Aus Tamper terminals on main
pcb closed circuit (i-on160 only)
Control unit 14.4V supply failed
(EUR versions only)
Control unit 14.4V supply restored
(EUR versions only)
Control unit 12V Aux DC not
working.
Control unit 12V Aux DC restored.
There is an error on loading the
control unit with its software.
Control unit battery restored.
Control unit battery failed load test.
Control unit battery missing or low.
Control unit battery restored.
Control unit battery charger failed.