Installer Menu Options
The text of the log entry that corresponds to the event causing the alarm.
The time and date of the alarm.
The name of the zone causing the alarm.
The control unit sends the text in the Home Message to every telephone number you have
programmed for SMS messages. The control unit also sends message 1 to telephone
number 1, message 2 to telephone number 2, message 3 to telephone number 3 and
message 4 to telephone number 4.
When programming SMS you key in the text of each message, link the messages to
specific triggers (groups of alarms), and then key in the telephone number you want each
message to go to. Figure 13 illustrates how triggers, messages and phone numbers are
linked.
Report Triggers
Tampers
Sets/Unsets
Call Mode
This option enables or disables SMS reporting. To employ SMS reporting set the call
mode to "Enabled".
Messages
To set up the text of SMS messages select Communications – SMS – Messages.
The bottom line of the display shows the first item in a list of the messages you can
program. Press  or  to scroll to the required message followed by  to select it. Then
key in the text and press  to finish.
The Home Message provides space for 12 characters. Use this text to identify the control
unit. Each of messages 1 to 4 provides space for 30 characters. Key in a message that
relates to the type of alarm event you select as a trigger (See "Triggers" on page 119).
Phone Book
To program the telephone numbers that the control unit will use for SMS message select
Communications – SMS – Phone Book. The bottom line of the display shows the first of a
Page 118
Alarms
System
Figure 13. SMS Message programming
Messages
Phone Book
Home message
Message 1
Tel No: 1234567 8
Message 2
Tel No: 8765432 1
Message 3
Tel No: 5678123 4
Message 4
Tel No: 2143658 7