i-on Range
Installer Menu Options
The keypad display shows the user number and name of the prox tag owner.

ARC Reporting

(For the i-on40, i-on30EX, i-on50EX and i-on160EX this option appears only when the i-
sd02, i-dig02 or i-gsm02 module is fitted. For the i-on30EXD and i-on50EXD this option is
always available. For the i-on16 this option appears only when the i-sd01 is fitted.)
The Test menu allows you to send a test call to either of the two telephone numbers you
have programmed to receive alarm information. The control unit must have a suitable
communications module fitted. ARC reporting must be enabled (see page 106 ).
From the Installer Menu select Test – ARC Reporting – Tel No 01 (or Tel No 02).
If the control unit uses SIA or CID reporting then the control unit starts the test call as soon
as you press . Press  to abandon the test call.
If the control unit uses Fast Format reporting then when you press  the keypad display
shows you the first in a list of the available Fast Format channels. Press  or  to scroll
up or down the list. Press  or  to select a channel for testing. Press  to start the test
call. The control unit sends a "T" (Test message) and the channel(s) you selected. If you
do not select any channels the control unit sends a "T" by itself.
During the test call the keypad display will show a sequence of progress messages.
If the call fails the keypad display will show a brief message giving the reason for failure.

Speech Dialler

(For the i-on40, i-on30EX, i-on50EX and i-on160EX this option appears only when the i-
sd02 or i-gsm02 module is fitted. For the i-on16 this option appears only when the i-sd01 is
fitted.)
The Test menu allows you to send a test speech call to any telephone number (not just the
ones programmed to receive speech messages in the event of an alarm).
From the Installer Menu select Test – Speech Dialler.
The keypad display shows a message asking you to key in a telephone number.
Key in the telephone number of the phone that you wish to receive the test message and
press .
When you press  the control unit starts the test call. The keypad display shows:
"Dialling...".
When the person at the receiving end answers the call the display shows "Connected...".
The control unit will play the home message followed by each of the four alarm messages,
and then repeat all five messages three more times. While the control unit is playing the
messages the keypad display shows "Playing messages...".
The person receiving the messages call acknowledge (and end) the call by pressing "5" or
"9" on their phone keypad.
If no-one acknowledges a test call the keypad display shows "No acknowledgement".

PSU Current

30 40 50 160
The Test menu allows you to check how much current the control unit is consuming. From
the Installer menu select Test – PSU Current. The bottom line of the keypad display shows
the current delivered by the PSU in the control unit.