Sign In
Upload
Manuals
Brands
Eaton Manuals
Security System
i-on30R
Eaton i-on30R Manuals
Manuals and User Guides for Eaton i-on30R. We have
3
Eaton i-on30R manuals available for free PDF download: Engineering Manual, Administration And User Manual, Installation Instructions
Eaton i-on30R Engineering Manual (156 pages)
Next Generation
Brand:
Eaton
| Category:
Security System
| Size: 2.41 MB
Table of Contents
About this Guide
2
Other Publications
2
Table of Contents
3
Chapter 1: Introduction
11
Introduction to I-On Next Generation Control Units
11
Summary of Features
11
System Architecture and Supported Peripherals
13
System Bus
13
Part-Setting and Partitioned Modes
14
Keypads
14
Alarm Communicators
16
Detectors (Zones)
17
Expanders
18
Outputs
18
Control Unit USB and Ethernet Ports
19
Sounders
19
Loudspeakers
20
Cameras
20
Remote Power Supplies
20
Remote Controls
20
Other Supported Radio Devices
21
Chapter 2: Planning the Installation
22
Choosing the Installation Locations
22
General Requirements
22
Control Unit
22
Keypads and Proximity Readers
22
External Sirens
23
Checking Power Availability
23
Worked Example
24
Detector (Zone) Wiring Types
24
Fully Supervised Loop (FSL)
24
4-Wire CC
25
2-Wire CC
26
Checking Cable Requirements
26
Screened Cable
26
Cable Segregation
26
Cable Configuration and Length
26
Bus Termination
27
Voltage Drop
27
Using Remote Power Supplies
28
Chapter 3: Getting Started
29
About the User Interface
29
Entering Text
29
Initial Power-Up Procedure
30
Entering the Installer Menu
32
Entering the Installer Menu from a Keypad
32
Saving Changes
32
Code Lockouts
32
Transferring to Another Keypad
33
Using Downloader or the Web Interface
33
Exiting the Installer Menu
33
Resetting (Defaulting) the System
34
Restoring Control Unit Factory Defaults
34
Resetting Device Addresses
34
Defaulting Access Codes
34
Chapter 4: Addressing and Zone Numbering
35
Bus Device Addresses
35
Bus Device Address for Devices that Communicate through a Radio Expander
35
Output Addresses
36
Detector Addresses and Zone Numbering
36
On-Board Wired Detectors
37
On-Board Radio Detectors
37
Detectors Attached to an Expander
38
Chapter 5: Installer Menu Map
41
Chapter 6: Detectors/Devices Menu
51
Detectors
51
Add/Del Detectors
51
Program Zones
51
Address Bus Device
60
Re-Scanning the Bus
61
Wired Expanders
62
Address Bus Device
62
Edit Expander
62
Delete Expander
63
Enable Expander
63
Replace Expander
64
Radio Expanders
64
Wired Keypads
64
Address Bus Device
64
Edit Keypad
64
Delete Keypad
66
Enable Keypad
67
Replace Keypad
67
Radio Keypads
67
I-Rk01
67
Key-Rkpz
69
External Sirens
70
Add/Del Siren
70
Edit Siren
70
Internal Sounders
71
Add/Del Sounder
71
Edit Sounder
71
Wams
71
Cameras
71
IP Cam 1
72
Chapter 7: Outputs Menu
73
Radio Outputs
73
Add Outputs
73
Edit Outputs
73
Wired Outputs
80
Panel
80
Plug-By Outputs
80
Plug-By Outputs on an EXP-PSU
81
Custom Outputs
81
Example
81
Chapter 8: Setting Options and Partitions Menus
82
About These Menus
82
Full Set, Part Set and Partition Options
82
Name
82
Exit Mode
82
Settle Time
84
Exit Time
84
Entry Time
84
Alarm Response
84
HUA Response
84
PZ Unset Response
85
PZ Set Response
86
PZ Reset Time
86
Siren Delay
87
Siren Time
87
Strobe on Set
87
Strobe on Unset
87
Part Set Exit Mode
88
Pt.set Settle Time
88
Part Set Exit Time
88
Pt.set Entry Time
88
Pt.set Alarm Resp
88
Pt.set Siren Delay
88
Pt.set Siren Time
88
Pt.set Final Exit
88
Pt.set Entry Route
88
Pt.set Strb Set
88
Remote Set
89
Exit Mode
89
Exit Time
89
Local Set on er
89
Calendar Set
89
Add Event
90
Edit Event
91
Delete Event
91
Add Exception
91
Edit Exception
91
Delete Exception
91
Deferring Calendar Setting
91
Setting Faults
92
Chapter 9: System Options Menu
93
Wired Zone Type
93
User Access
93
HUA Keys Active
93
Quick Set
93
Quick Omit
94
User Code Reqd
94
Way Replies
94
Way Set Instant
94
Duress Enable
94
Terminated Set
94
User Reset
95
Zone Alarms
95
Zone Tampers
95
System Tampers
95
Confirmation
96
Confirmation Mode
96
Confirmation Time
96
After Entry
97
Entry Keypad Lock
97
Sounder on
97
Siren on
98
Unconfirmed Reset
98
Confirmed Reset
99
HUA Confirm Time
99
Tamper as Tamper Only
99
Masking
99
Alarm Response When the System Is Unset
100
Alarm Response When the System Is Set
100
Mask Override
101
Language
101
Shunt Groups
101
Restore Defaults
102
Staged Defaults
102
Factory Defaults
102
Installer Name
103
Installer Code
103
Keypad Text
103
Remote Needs Entry
103
Remote Entry Part Set
103
RKP Needs Entry
104
RKP Entry Prtst
104
HUA Response
104
PZ Unset Response
104
PZ Reset Time
104
Auto Rearm
105
Panel Loudspeaker
105
Volume
105
Partitions
105
Entry Alarm Delay
105
Abort Time
105
Supervision
106
Jamming
106
Force Set
107
Tamper Omit
107
CSID Code
107
Silence Alerts
108
Mains Fail Delay
108
External Psus
109
Set Time & Date
110
SNTP Time Sync
110
Panel Tamper Return
110
Level 4 Updates
111
Panel Upgrade
111
Chapter 10: Communications Menu
112
Contacts
112
ARC Reporting
112
Call Mode
112
Telecomms Priority
112
Recipients
113
Account Numbers
113
Report Type
113
Fast Fmt Channels
113
CID/SIA Events
115
Restorals
119
Burg Comms Rearm
119
21CN FF Ack Time
119
Send Tamp as Burg
119
Dynamic Test Call
119
Static Test Call
120
Unset Comms
120
Speech Dialler
120
Call Mode
121
Messages
121
Triggers
122
Destinations
122
Call Acknowledge
122
Sms
122
Outgoing
122
Incoming
123
Pstn Sms
124
Email
124
Call Mode
124
Messages
125
Triggers
125
Destinations
125
Server
125
Line Fail Response
125
Line Fail Delay
126
IP Network (Own)
126
Web Server
126
Downloader
127
M2M Interface
127
IP Address
127
IP Subnet Mask
127
Gateway IP Address
127
DNS IP Address
127
Module Ethernet
127
GPRS Module
128
Dynamic DNS
128
Downloading
129
Account
129
Connection Type
129
Rings to Answer
130
Answer on One Ring
130
Access Mode
130
Phone Book
131
IP Network
131
Secure Callback
131
Modem Baud Rate
131
Remote Servicing
132
Chapter 11: Test Menu
133
Sirens and Sounders
133
Ext. Radio Sirens
133
Wired Sirens
133
Wired Keypads
133
Key-Rkpz
133
Internal Sounders
133
Wired Keypad
133
Radio Keypads
134
I-Rk01
134
Key-Rkpz
134
Expanders
134
Radio and Wired Expanders
134
EXP-Psus
134
Walk Test
135
Zone Resistances
136
Signal Strengths
136
Outputs
137
Radio/Wired/Plug-By/Expander Outputs
137
Comms Channels
137
Remotes
138
User Hold up Alarms
138
Prox Tags
138
ARC Reporting
138
Speech Dialler
139
Sms
139
Email
139
PSU Current
139
Locate Bus Device
139
Chapter 12: View Log Menu
140
Mandatory and Non-Mandatory Log Events
140
How the Log Displays User Identities
140
Downloader and the Log
141
Logging Tamper Events
141
Logging Software Updates
141
Chapter 13: About Menu
142
Panel
142
Expanders
142
Keypads
142
Comms
142
Panel Ethernet
142
Module
143
Zone Mapping
143
Zone Numbers
143
Zone Addresses
143
Appendix A: ARC Communication Formats
144
Fast Format
144
Contact ID
144
SIA 1, SIA 2, SIA 3 and Extended SIA 3
145
Extended SIA3 V2
145
Appendix B: System Maintenance
146
Inspections
146
Replacing or Removing Devices
146
Removing a Plug-On Module
146
Removing a Bus Device Permanently
146
Replacing a Bus Device
147
Using Leds for Bus Diagnostics
147
Appendix C: Log Messages
148
Introduction
148
Log Messages
148
Email Error Messages
152
TCP/IP Error Messages
153
Overview of the SSL-Relevant Messages
154
Advertisement
Eaton i-on30R Administration And User Manual (68 pages)
i-kp01; KEY-K01; KEY-KP01; KEY-KPZ01; KEY-RKPZ; i-RK01; KEY-FKPZ
Brand:
Eaton
| Category:
Security System
| Size: 1.23 MB
Table of Contents
Compliance Statement
2
Table of Contents
3
Chapter 1: Introduction
5
About this Guide
5
Part-Setting and Partitioned Modes
5
Part-Setting Mode
5
Partitioned Mode
6
System Components
7
The Control Unit
7
Detectors (Zones)
8
Outputs
9
Keypads
9
Proximity Tags
13
Remote Controls
13
Radio Hold up Alarms (HUA)
13
About Users
14
User Access Codes
16
Installer Access
17
Eaton Secureconnect
17
Chapter 2: Setting and Unsetting
18
Introduction
18
Using a Keypad
18
Setting the System
18
Quick-Setting the System Using a Keypad
21
Unsetting the System Using a Keypad
22
Using a Two-Way Keyfob-Style Remote Control
23
Setting the System
24
Unsetting the System
24
Querying the Set/Unset Status
24
Starting a Hold up Alarm (HUA)
25
Using a One-Way Remote Control
25
Setting the System
26
Unsetting the System
26
Using a One-Way Radio Keypad
27
Setting the System
27
Unsetting the System
28
Using SMS Command Messaging
28
Chapter 3: Managing Alarms
29
Alarm Types and Sounds
29
Other Alarm Actions
30
Speech Messages
31
Silencing, Acknowledging and Resetting Alarms
31
Installer Resets
33
Accidental Alarms
33
Viewing Alerts
33
Chapter 4: User Menu Options
35
User Menu Map
35
Entering and Exiting the User Menu
37
Entering Text
37
Omitting Zones
38
Using Shunt Groups
39
About Shunt Groups
39
Activating or Deactivating a Shunt Group
40
Managing Users
40
Changing Your Access Code or Assigned Devices
41
Adding Users
41
Editing Users
44
Deleting Users
45
Viewing the Log
45
User Numbers
46
Testing the System
46
Testing Sirens and Sounders
46
Testing a Wired Keypad
47
Performing a Walk Test
48
Testing Outputs
49
Testing Remote Controls
50
Testing User Huas
51
Testing Proximity Tags
51
Testing ARC Reporting
52
System Configuration
53
Switching Facilities On/Off
53
Setting the Date and Time
54
Configuring Calendar Sets
54
Defining Contacts
58
Editing Outputs
59
Managing Remote Controls
61
Starting a Call to Downloader
65
Switching Outputs On/Off
66
Using the about Options
66
Generating a Secureconnect Pairing Code
67
Eaton i-on30R Installation Instructions (2 pages)
Brand:
Eaton
| Category:
Control Unit
| Size: 0.54 MB
Advertisement
Advertisement
Related Products
Eaton i-on30EXDL
Eaton i-on30EXL
Eaton i-on30EX
Eaton i-on30EXD
Eaton i-on30R+
Eaton i-on16
Eaton i-on1000EX
Eaton i-on Series
Eaton Scantronic i-onG3LM
Eaton i-onG3MM
Eaton Categories
UPS
Circuit breakers
Industrial Equipment
Switch
Industrial Electrical
More Eaton Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL