i-on Range
MENU Option
Zone tampers
System tampers
Confirmation
Sounder on
Siren on
Confirmation
Confirmation Mode
DD243
BS8243
Basic
Confirmation time
After Entry
Entry Keypad Lock
Sounder on
Siren on
Unconfirmed reset
Confirmed reset
HUA Confirm time
Tamper as Tamper-only
Profiles
Masking
Mask Override
Language
Restore Defaults
Staged defaults

Factory defaults

Country Defaults
Installer Name
Installer Code
Keypad text
Remote needs Entry
Remote Entry PrtSt
RKP needs Entry
RKP Entry PrtSt
HUA Response
Auto Rearm
Factory Default
Grade 2: Yes
Grade 3: No
No
(-EUR Version)
Unconfirmed
Unconfirmed
(-UK Version)
Default for UK systems.
30 minutes
1 zones
Off
Unconfirmed
Unconfirmed
User
Installer
8 hours
Enabled
Grade 2: Off
Grade 3: On
On
English
"Installer"
Grade 2: "7890"
Grade 3, "567890"
Disabled
Disabled
Disabled
Disabled
Audible
Never
The Installer Menu
Notes
For INCERT approval set to NO.
EUR versions always use Basic
Confirmation.
Not available for EUR versions.
Not available for EUR versions.
Visible for DD243 or BS8243.
Can be adjusted between 1 and 60
minutes. Note that only values of
30 minutes or more comply with
DD243 or BS8243.
Visible for DD243 or BS8243.
Default changes to 2 zones when
Confirmation Mode = DD243.
Visible for DD243 or BS8243.
Visible for DD243, BS8243 and
Basic.
Visible for DD243, BS8243 and
Basic.
Visible for DD243 or BS8243.
Visible for DD243 or BS8243.
Visible for BS8243 only. Must be
between 8 and 20 hours in order to
comply with BS8243:2010
16 40
30 40 50 160 Masking
"ON" is required in order to comply
with EN50131-1, 8.2.1.
30 40 50 160 Appears
only when Masking is On.
This option does not appear in UK
versions.
30 50 160
i-on30EX cannot change to 6-digit
user codes.
Appears on EUR systems only, as
part of Factory Default process.
Required for web browser login.
i-on16, i-on30EX, and i-on40
Grade 2 only.
Depends on control unit type.
Appears here only in part setting
system.
This setting is required in order to
Page 39

Advertisement