Installer Menu Options
Confirm
When the system is set the control unit does not activate the siren(s) until
a confirmed alarm occurs.
Note: The control unit will not allow you to select "Siren on - Unconfirm" at the same time
as "Sounder on - Confirm".
The Sounder On and Siren On options are both affected by the Siren Time and Siren
Delay (see page 81), as follows:
Sounder On Unconfirm/Siren On Unconfirm
Unconfirmed alarm: internal sounders and sirens start immediately and run for the
programmed siren time (see page 81).
Confirmed alarm: the control unit restarts the sirens and internal sounders, which run for
the full programmed siren time (even if that had expired earlier).
Sounder On Unconfirm/Siren On Confirm
Unconfirmed alarm: the internal sounders start immediately and run for the programmed
siren time.
Confirmed alarm: the control unit waits for any programmed siren delay (see page 81) and
then starts both the internal sounders and the external sirens. These both run for the
programmed siren time.
Sounder On Confirmed/Siren On Confirmed
Unconfirmed alarm: No sounders or sirens.
Confirmed alarm: Control unit waits for Siren Delay, and then starts both internal sounders
and external sirens. Both sirens and sounders run for the full siren time.
Unconfirmed Reset
If you select either "DD243" or "BS8243" for Confirmation Mode then this option overrides
System Options - User Reset – Zone Alarms (see page 88). You may then use the
options below:
User
The user can reset after an unconfirmed alarm.
Installer
The user cannot reset after an unconfirmed alarm, the installer must do it.
Notes:
1.
If a user causes an alarm which would require Installer reset then they have a time
to abort the alarm, which they can then reset themselves. The time allowed for
aborting the alarm can be set by the Abort Timer, see page 100.
2.
These options apply to intruder alarms only and not to HUAs.
Confirmed Reset
If you select either "DD243" or "BS8243" for Confirmation Mode then this option overrides
System Options - User Reset – Zone Alarms (see page 88). You may then use the
options below:
User
The user can reset after a confirmed alarm.
Installer
The user cannot reset after a confirmed alarm, the installer must do it.