Eaton i-on series Engineering Manual page 115

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

i-on Range
Menu item
ARC Reporting
Deals with reporting to a central station using either SIA, CID
or Fast Format.
Speech Dialler
Deals with recording speech messages, selecting the alarm
types that will trigger them, and selecting destinations for the
messages.
SMS
Deals with setting up text messages, selecting the alarm
types that will trigger them an selecting their destinations.
Line Fail Reporting
Allows you to select how the control unit reports a
communications failure.
IP Network (Own)
When NO Ethernet or GPRS module is fitted this sub-menu
deals with setting the control unit's own IP address and
access to the built in web browser interface.
With an Ethernet module is fitted this sub-menu ALSO allows
you to set up the IP address and other parameters for any
attached Ethernet or GPRS modules. These extra sub-menus
will not appear if the modules are not fitted.
IP Network (Own)
For i-on30EX the IP Network (Own) sub-menu allows you to
set up the IP address and other parameters for any attached
Ethernet or GPRS modules. This control unit does NOT have
a web browser interface.
Downloading
Deals with setting up phone numbers, account numbers for
the downloader, and controlling the type of connection you
wish to allow.
Note: Eaton's Security Business do not recommend using the i-gsm02 for Fast Format
communications. The GSM network introduces too great a variation in the delay
between signal and response. Tests carried out by Eaton's Security Business show
that different cell towers from the same providers give different results.
The control unit is designed to alert the user if it fails to complete a programmed
communication. If alarm reporting fails then the keypad displays an alert by lighting the red
LEDs around the navigation keys. Although the user may acknowledge the alert, the
control unit will not remove the alert until communication is completed successfully.
If you wish to remove a communications module from a system, ensure that you first
disable communications in the appropriate menus:
To remove a:
i-sd01, i-sd02, i-gsm02
i-dig02
GPRS, Ethernet
Otherwise the control unit will continually report a communications failure.
Disable:
ARC Reporting, Speech Dialler, SMS
ARC Reporting, SMS
ARC Reporting, IP Network
Installer Menu Options
Available with:
i-on16+i-sd01, i-
on30EXD, i-on50EXD,
i-sd02, i-dig02, i-gsm02
(see note)
i-on16+i-sd01, i-sd02, i-
gsm02
i-on16+i-sd01, i-
on30EXD, i-on50EXD,
i-sd02, i-dig02, i-gsm02
i-on16+i-sd01, i-
on30EXD, i-on50EXD,
i-sd02, i-dig02, i-gsm02
40 50 160
30
30 40 50 160
Page 105

Advertisement

Table of Contents
loading