Eaton i-on series Engineering Manual page 123

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

i-on Range
Burg Comms Rearm
(This menu appears only if you select "Fast Format" in Communications - Report Type.
AND if System Options – Confirmation – Confirmation Mode is set to "Basic".) This menu
option determines what the control unit does with the "Burg" Fast Format channel 3 at the
end of the siren run time. There are two options:
Disabled
The channel stays active until an Installer or user resets the system.
Enabled
The system rearms Channel 3 once the siren timer has expired. Once the Channel is
rearmed, the system is ready to report any new alarm. The system bypasses any
detectors that are still triggered.
Notes:
If a Final Exit Zone is triggered, Channel 3 becomes active at the end of the
Programmed Entry time.
21CN FF Ack Time
(This menu appears only if you select "Fast Format" in Communications - Report Type.
The menu does NOT appear if a GPRS or Ethernet module is fitted.)
A PSTN line connected to a BT21CN line (or equivalent) will take longer to acknowledge a
Fast Format transmission. This option allows you to adjust the length of time that the
control unit waits for the ARC acknowledgement. You can adjust the acknowledgement
time from a minimum of 400ms up to a maximum of 1200ms in 100ms steps.
Send Tamper as Burg
When using CID or SIA reporting this option allows you to program the control unit to send
tampers as alarm.
If you select Disabled, (the default) then the control unit sends all CID/SIA messages as
specified in Communications – ARC Reporting – CID/SIA Events.
If you select Enabled then for full alarm response the control unit sends tampers as
burglary (BA) and sends Contact ID 130 in place of Contact ID 137.
Dynamic Test Call
Note: If this option is not visible then static test calls are enabled. To use dynamic test calls
disable static test calls first.
In dynamic testing the system makes a test call 24 hours after the last alarm
communication. To enable dynamic testing select Communications – ARC Reporting –
Dynamic Test Call – Enabled.
Static Test Call
Note: If this option is not visible then dynamic test calls are enabled. To use static test calls
disable dynamic test calls first.
In static testing the system makes a test call either on:
Every day at one particular time of day or
On the same day of every week, or
On one day every month.
To make test calls at a set time every day select Communications – ARC Reporting –
Static Test Call – Daily. From the display select a number between 01 and 24 to choose
the time of day for the call. For example, select 18 to program the control unit to make a
static test call at 6:00pm every day.
Installer Menu Options