Eaton i-on series Engineering Manual page 101

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

i-on Range
BS8243
Selecting this option reveals all of the same sub-menus as the DD243
option, but also reveals a sub-menu for programming confirmed HUA.
In addition, selecting "BS8243" hides the "2 zones" option in "After Entry"
(see below).
Confirmation Time
This option determines the length of the confirmation time for intruder alarms. You
can select any time between 1 and 60 minutes.
Note: Confirmation times between 1 and 29 minutes do not comply with DD243 or
BS8243.
After Entry
Never
The control unit turns alarm confirmation off if the user enters by the entry
door (used for DD243:2004 clauses 6.4.2 and 6.4.4 and DD8243:2010).
1 zone
The control unit starts a confirmed alarm if the intruder activates one or more
zones, not on the entry route, after entering the premises through the final
exit zone.
2 zones
The control unit starts a confirmed alarm if an intruder activates two (or more)
zones, not on the entry route, after entering the premises through the final
exit zone (used for DD243:2004 clauses 6.4.5) Note: This option is not visible
if you have selected BS8243 as the Confirmation Mode.
Entry Keypad Lock
This option determines whether the user can unset the system by entering an access code
after opening the entry door.
Off
The user can enter an access code at the keypad after the entry door opens
(used for DD243:2004 clause 6.4.4).
On
The user must unset the system by some means other than the keypad, for
example prox tag, remote control or key-switch (used for DD243:2004 clause
6.4.5 and BS8243:2010 6.4.5b).
Notes:
1) This option has no effect if the alarm response (for either full set or part set) is set
to "Siren" or "Internal". In those cases the user will still be able to unset the system
using an access code. Entry Keypad Lock is intended for use when the system can
summon a police response.
2) In a partitioned system Eaton's Security Business advises that you use Entry
Keypad Lock in conjunction with Partition Users. The Master User or Normal Users
can unset a partition from a keypad that is not specifically allocated to that partition,
and so bypass Entry Keypad Lock.
Sounder on
Unconfirm
When the system is set the control unit activates the internal sounders
when an unconfirmed alarm occurs.
Confirm
When the system is set the control unit does not activate the internal
sounders until a confirmed alarm occurs.
Note: The control unit will not allow you to select "Sounder on - Confirm" at the same time
as "Siren on - Unconfirm".
Siren on
Unconfirm
the control unit operates the siren for all alarms (and overrides any Siren
Delay).