2. A user can now make only four attempts (instead of 10) before code lockout. After four
attempts the system generates a tamper condition.
3. A Duress Code user is blocked from all menus. A Duress code can only set/unset
system. A Duress code cannot have a prox tag or any remotes or HUDs.
4. Using a Duress code does not prevent other HUDs from starting an alarm.
5. A user can now set other partitions when the calendar set warning timer is running.
They do this by pressing the menu key, and the system shows them the normal setting
options.
6. An External Warning Device fault now prevents setting and cannot be overridden when
configured for EN50131 Grade 3. This fault can only be overridden for Grade 2.
7. For the Master User, Calendar Set now has two new warning timer options, see
"Partitions/Setting Options Menu" below.
8. A Master User can now make a test call to the ARC. This new feature helps installers
to clear PSTN alarm fail and line fail conditions without attending the site.
For Installers:
1. The i-kp01 ABCD LEDs now show the set status in partitioned systems with four
partitions or less (i-on40 and i-on30).
Detectors/Devices Menu:
1. There is a new HUD fault zone type.
2. The Ext PSU AC fail, Ext PSU battery fault, Ext PSU fault, WD fault and HUD fault
zone types are not available on radio devices.
3. There is a new Reset attribute for zones connected to shock and vibration sensors.
4. Tampers on Fire or Technical Alarm zones now cause an internal alarm instead of an
alert.
Partitions/Setting Options Menu:
1. Calendar Set now has two warning timer options: "Warning Time" and "Warning Tone".
Outputs Menu:
1. Output type "HUA confirm" now triggers on any two qualifying events. (two HUAs or
HUA plus tamper in any order).
2. There is a new output type: "Burg confirmed". This output triggers on any two qualifying
events (two Normal Alarms or Normal Alarm plus tamper in any order).
(These modifications are to help ARCs which cannot correctly differentiate between
confirmed Burgs/HUA using existing outputs and messages.)
3. A Failed soak test no longer contributes to a General Fault.
4. The A/C Fail output type now restores as soon as the fault clears, and does not wait for
the user to acknowledge/clear the fault.
System Options Menu:
1. There is a new option "2-way Set Instant" in User Access.
2. There is a new option "Remote needs entry" for a part set.
3. The entry alarm delay has changed from 45s to 30s.
Communications Menu:
1. Fast Format now has three new channels to provide separate signals for Duress, HUA
confirm and Burg confirm.
2. The HUD/HUA SIA/CID report codes have been corrected: