Eaton i-on series Engineering Manual page 65

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

i-on Range
Expander Loudspeaker Volume
To change the volume of notification tones from loudspeakers attached to expanders use
the Detectors/Devices – Wired Expander – Edit Expander – Loudspeaker volume menu.
Press  to lower the volume or  to raise the volume. The display shows the current
volume setting by a row of stars (for example "****"). This volume control does NOT
change the volume of alarm tones, the control unit will still give these at full volume.
Note: You can also press one of the number keys to specify the volume in a range 0 to 9.
For example, pressing "8" gives you eight stars on the display.
Press  to leave the menu.
Note: When you first add an expander to the bus, the control unit defaults the loudspeaker
volume to zero.
Wired Expanders Zone Wiring
You can change the zone wiring method for each wired expander individually.
During commissioning the Installer can select a system-wide zone wiring method as part of
the initial power-up (see the relevant Installation Manual). If you wish to change the zone
wiring method for an individual Expander use the Detectors/Devices – Wired Expander –
Edit Expander – Wired Zone Type menu.
For an EXP-W10:
The zone wiring types available are: 4-wire CC, 2-wire CC, 2k2/4k7, 1k0/1k0, 2k2/2k2,
or 4k7/4k7.
When using 4-wire CC wiring each EXP-W10 expander provides connections for five
zones.
When using 2-wire CC wiring, each wired expander provides connections for ten
zones. Program at least one zone on the expander as type "Tamper" to act as a
connection point for a common tamper zone.
For an EXP-WCC:
The zone wiring types available are:
2K2/4K7/4-wire CC
2-wire FSL 1K/1K
2-wire FSL 2K2/2K2
2-wire FSL 4K7/4K7
2-wire FSL 1k/1k
When using the 2K2/4K7/4-wire CC option the EXP-WCC provides connections for 10
zones.
When using FSL wiring each wired expander provides connections for 10 zones.
NOTE: If you change the overall system zone wiring type (see page 86) AFTER selecting
the expander wiring type then the expander will adopt the wiring type you selected
for the system. You must then re-enter the expander menu to change the expander
zone wiring type back to the one you want the expander to use.
Battery 2
30 50 160
This option is available when editing an EXP-PSU. You can use the option to enable or
disable alert reporting on a second backup battery that may be fitted within the EXP-PSU.
The options are:
Installer Menu Options