Installer Menu - Eaton i-on series Engineering Manual

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

i-on Range
Important: Where noted below the defaults listed enable the control unit to comply with
EN50131 requirements. If you change those settings then the installation may no longer
comply. If the control unit does not comply with EN50131 you must remove any labelling
that indicates compliance.
MENU Option
1 DETECTORS/ DEVICES
Detectors
Add/Del Detectors
Exp. R1-nn
Zone nnn...
Delete all
Program Zones
Zone 000...159
(see note)
Name
Type
Partitions
Attributes
Address Bus Device
Wired Expanders
Address Bus Device
Edit Expander
Expander W1-01...W1-45
Name
Partitions
Wired zone type
Loudspeaker volume
Battery 2

Installer Menu

Factory Default
"Zone nnn"
Not used
None
Chime: No
Soak Test: No
Double Knock: No (not i-on16)
Part Set B: No
Part Set C: No (level setting system only)
Part Set D: No (level setting system only)
Part Set: No (partition system only, not on i-
on16)
Omittable: No
Force Set Omit: No
Masking: No (not i-on16)
Inverted: No (not i-on16)
Shock No
Roller Shutter: No (see notes)
Reset: No
"Exp. W1-nn"
Partition 1.
FSL 2k2/4k7
Zero when expander first added to bus.
Disabled
Notes
30 50 160
First radio expander with spare
zones
Appears only if a radio expander is
available on the bus.
Zone number depends on
expander number.
Deletes all radio zones on the
selected expander.
Actual number of zones depends
on panel type and expanders
fitted.
30 40 50 160
Appears only in a Partitioned
system and when zones have a
type other than "Not Used".
Appears when zone is given a type
other than "Not Used".
Some attributes are only available
on particular zone types.
Double Knock does not comply
with EN51031.
Masking must be enabled in
System Options.
(Roller Shutter is available only on
i-on160EXEUR.)
30 50 160
30 50 160
Display shows expanders currently
addressed on bus. Max number
depends on control unit type.
nn is between 01 and 45,
depending on control unit type.
Appears only in a partitioned
system.
(Alarm and tamper tones always
be emitted at 100%.)
Appears only for EXP-PSU
Page 33