Installer Menu Options
The Installer code allows you to enter the Installer Menu, and carry out an Installer reset.
However, the Installer code does not allow you to set or unset the system.
40 50 160 When logging into the i-onEX Web browser interface you must key into
the password field the same code as you have programmed into the Installer Code field.

Keypad Text

If required the installer can key in a text message that appears on the first line of the
display in the standby screen. This could be, for example, the name of the installer's
company. See page 18 for hints on editing text.

Remote Needs Entry

Instead of using an entry timer triggered by a Final Exit zone to allow the user to gain
access to the control unit and unset the system (or a partition), the user can employ a
remote control. To choose between either of these options select: System Options –
Remote needs Entry. The options available are:
Enabled
The user must first trigger a Final Exit zone and start the entry timer before
unsetting a Full Set system or partition with a remote control. The system
unsets those partitions the user is assigned to that have an active entry
timer. If a partition that the user is assigned to does not have an active
entry timer then the partition remains set.
Disabled
The user can unset the system or partition using a remote control without
first starting the entry timer. The system unsets all partitions that the user is
assigned to.

Remote Entry Part Set

In a Part Set system or partition, instead of using an entry timer triggered by a Final Exit
zone to allow the user to gain access to the control unit and unset the system, the user
can employ a remote control. To choose between either of these options select: System
Options – Remote needs Entry PrtSt. The options available are:
Enabled
The user must first trigger a Final Exit zone and start the entry timer before
unsetting a Part Set system or partition with a remote control. The system
unsets those partitions the user is assigned to that have an active entry
timer. If a partition that the user is assigned to does not have an active
entry timer then the partition remains part set.
Disabled
The user can unset a Part Set system or partition using a remote control
without first starting the entry timer.

RKP Needs Entry

Instead of using an entry timer triggered by a Final Exit zone to allow the user to gain
access to the control unit and unset the system (or a partition), the user can employ a
radio keypad. To choose between either of these options select: System Options – RKP
needs Entry. The options available are:
Enabled
The user must first trigger a Final Exit zone and start the entry timer before
unsetting the system (or partition) with a radio keypad. The system unsets
those partitions the user is assigned to that have an active entry timer. If a
partition that the user is assigned to does not have an active entry timer
then the partition remains set.
Disabled
The user can unset the system using a radio keypad without first starting
the entry timer. The system unsets all partitions that the user is assigned
to.