Basic Programming Procedures

To Enter the Installer Menu by Keypad:

1.
Make sure the system is fully unset and showing the
standby screen (time and date).
Note that although the example at the right shows "i-
on160EX" on the top line, if you are using another
control unit, the text will show the name of that control
unit.
2.
Key in the Installer access code. When delivered from
the factory, at Security Grade 2 the default Installer
access code is "7890". The default user code is "1234".
(Note that at Security Grade 3 on the i-on50EX and i-
on160EX the codes are "567890" and "123456"
respectively.)
As you start to key in the code the display shows:
When you key in the last digit of the access code the
display MAY show:
If this happens key in a valid user code (not a Set Only
user code see note 1).
When you key in the last digit of the access code the
display shows "Installer Menu" on the top line. The
bottom line shows the first option in the Installer menu:
Detectors/Devices. (See "Code Lockout" on page 12)
Press  or  to display more options from the menu.
3.
Each option appears on the bottom line of the display
in turn, for example:
Press  or  to select that option of the menu.
4.
The option you selected now appears on the top line. If
there are any sub-options for that selection, then the
first of them appears on the bottom line. Press  or 
to display the other sub-options.
Note: After you initially gain access to the Installer Menu, you may leave and re-enter
using the Installer access code by itself for up to 30 minutes after you last exited the
Installer Menu. After that time, or if the system is armed then disarmed, you will need
to enter a valid user access code to complete your entry into the Installer Menu (note
that you cannot use a Set Only user code). To disable this feature see System
Options – User Access – User Code Required on page 87.
Code Lockout – Excess Keys Tamper
If any user (including the installer) keys in their access code incorrectly, the keypad display
shows the time and date again, and gives an error tone. Key in the access code again, but
ensure that it is correct.
If any user keys in a total of four consecutive incorrect access codes then the system
starts a tamper alarm and locks all users out of all keypads for 90 seconds. This event is
recorded in the log as "Excess Keys Tamper" together with the number of the keypad at
which this occurred.