Account Number - Eaton i-on series Engineering Manual

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

The Installer Menu
MENU Option
Panel Loudspeaker
Loudspeaker 1 (or 2)
Volume
Partitions
01...04 (i-on30)
01...04 (i-on40)
01...05 (i-on50)
01...20 (i-on160)
Entry Alarm Delay
Abort Time
Supervision
Jamming
Force Set
Tamper Omit
CSID Code
Silence Alerts
Mains Fail Delay
Battery 2
Set Date & Time
Panel Tamper Return
5 COMMUNICATIONS
ARC Reporting
Call Mode
Phone book
IP Network

Account Number

Report Type
Fast Format channels
CID/SIA Events
Page 40
Factory Default
****
Yes
Enabled
120 seconds
Tamper
Tamper
Off
Disabled
0000
User Code
0 minutes
Disabled
CC
Single
Empty
000000
Fast Format
UK
Channel 1: Fire Alarm
Channel 2: Hold Up Alarm
Channel 3: Burglar Alarm
Channel 4: Open / Close
Channel 5: Zone Omit (System)
Channel 6: Tamper
Channel 7: Confirmed Alarm
Channel 8: General Fault
Fire Alarm: Yes
Hold Up Alarm: Yes
Burglar Alarm: Yes
Notes
comply with EN50131.
Appears in EUR versions, OR only
when System Options –
Confirmation Mode is "Basic".
(Two loudspeakers on i-on160EX.)
30 40 50 160 Appears
only in a Partitioned system.
Assigned to all partitions. Number
of partitions depends on panel
type.
This setting is required in order to
comply with EN50131 8.3.8.2.
This setting is required in order to
comply with EN50131.
This setting is required in order to
comply with EN50131.
160. This value depends
on how you answer the Battery 2
monitoring question during the
initial start-up.
Only visible on i-on30EXD and i-
on50EXD or when suitable
communications module fitted.
To comply with EN50131 the panel
must have a communicator.
A "single" or "alternate" setting is
required in order to comply with
EN50131.
Only visible when suitable
communications module fitted.
Part setting system has one
account number. A partitioned
system has one account number
per partition.
Appears only when Report
Type=Fast Format
1. In EUR versions Channel 5 is
Zone Omit (Setting) by default.
(see Note 1)
Notes:
1. Appears when Report Type=CID
or SIA.
i-on Range