Note: Before programming the control unit to use the IP Network please make sure that:
1. You understand basic IP terminology.
2. You have obtained the necessary information from your Internet Service Provider.
Unit Name
Use this option to store a unique name for the unit.
Polling IP Address
Key in the IP address of the remote polling engine. If the ARC is not using a polling
engine then leave this option blank.
ARC IP Address
Use this option for the ARC's main IP addresses. This option provides two entries for
storing a primary and a secondary ARC IP address.
Account Numbers.
To store an ARC account number select Communications – ARC Reporting – Account
Numbers.
If you are programming a partitioned system then the control unit gives you the opportunity
to store an account number for each partition. If you are programming a Part Setting
system then you can store one account number.
With CID reporting the system reports alarms using a four digit account code.
With Fast Format reporting you can use four-, five- or six-digit codes. The control unit pads
five-digit codes to six digits using a leading zero. The control unit leaves four- and six-digit
codes unchanged.
Note: If you need to add a letter to the account code press the numbers keys repeatedly
until the letter you want appears on the display. See page 18.
Report Type
To choose the report type to send to the ARC select: Communications – ARC Reporting –
Report Type.
The report types available are: Fast Format, Contact ID, SIA 1, SIA 2, Scancom SIA 3,
Extended SIA 3 and Extended SIA3 v2.
Fast Format Channels
(See Appendix I for a brief description of Fast Format.)
Note: Eaton's Security Business does not recommend using the i-gsm02 for Fast Format
communications. The GSM network introduces too great a variation in the delay
between signal and response. Tests carried out by Eaton's Security Business show
that different cell towers from the same providers give different results.
If you selected Fast Format in Report Type then you can select Communications - ARC
Reporting - Fast Format Channels to allocate an event to each of eight channels. Table 3
below shows the factory default events for each channel. Table 4 shows the available
events.
The factory default allocation of events to channels is:
Channel
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Table 3. Fast Format Channel Factory Defaults
Event
Fire Alarm
Hold Up Alarm
Burglar Alarm
Open/Close
Zone Omit (System) (see note)