Installer Menu Options
Zones
When you select a Walk Test option (apart from the Chime option), the display shows the
first item in a list of the detectors available for test. Walk around the area you wish to test
and trigger each detector. If the Chime option is set to "Yes" then every time you trigger a
detector the keypads and loudspeakers give confirmation tone. The bottom right of the
display shows an "A" if you trigger the Alarm input and a "T" if you trigger the Tamper.
Note that if a zone has the Masking attribute enabled and the device is masked during the
walk test then the keypad display will also show a "T".
The top of the display shows the number of zones left to test. The control unit decreases
the number of zones every time you trigger an individual Alarm input.
The bottom line of the display shows the zone name. To see the zone number press  or
.
Press  to end the test.
Note: Use the Walk Test option to test wired HUA switches. While you are using the Walk
Test option activating a wired HUA switch will not cause a HUA alarm.
If you wish to see which zones have not yet been tested then press the menu key. The
bottom line of the display will show the first in a list of those zones remaining to test. As
you test each zone it will disappear from the display. Press the menu key again to return to
the full list of zones.
Testing Roller Shutter Detectors
160EX EUR
When testing roller shutter detectors pull out the string so that the sensor makes the
required number of clicks within 20s.
Testing Shock Sensors
When testing shock sensors create suitable sized impacts near the sensor.
Adjusting Roller Shutter and Shock Sensor Sensitivity
160EX EUR
If you wish to change the sensitivity of roller shutter detectors then go to
Detectors/Devices – Detectors – Program Zones, select the appropriate zone and adjust
the sensitivity figure. Remember to leave Installer Menu to save the new figure before re-
testing the zone.

Zone Resistances

30 40 50 160
Note: This menu item will also be available on the i-on16 when it is connected to a KEY-
KPZ01.
When you select Zone Resistance, the display shows the first of the available wired
detectors. Press  or  to see the other detectors in the list.
The bottom line of the display shows the zone name. To see the zone number press  or
.
Page 130
This option lets you select one or more individual zones, and
test only those zones and no others.
Use  or  to scroll up and down the list of zones. Press  or
 to display "Yes" at the end of the bottom line to mark the
zone as one you want to test.
i-on Range

Advertisement

Table of Contents
loading

Table of Contents