Installer Menu Options
IP Port Number
Secure Callback
Select Downloading - Secure Callback to allow Downloader to use a third callback number
(independent of the telephone numbers in the Downloading – Phone Book option). Before
making a Downloader connection, the remote PC operator keys in the third callback
number. Once connected Downloader transmits the number to the control unit. The control
unit then uses that number to call back to the remote PC.
Modem Baud Rate
(This option is not present when an i-gsm02 module is fitted.) Over some noisy telephone
lines Downloader communicates more effectively using a slower Baud rate from the
control unit. Select Downloading – Modem Baud Rate to change the baud rate to 300
baud.
Remote Servicing
(Available in UK versions of i-onEX control units only.)
The options available under the Downloading – Remote Servicing menu item are
intended for use with Eaton's Security Business's Remote Servicing feature on
Downloader. This feature must be set up by a Eaton's Security Business External Support
Manager. Please contact your Eaton's Security Business Account Manager for more
details.

Plug-by

This option controls the line fail reporting from any plug-by module connected to the
control unit.
Note: The Line Fail pin on the control unit's plug-by connector must be connected to the
appropriate output on the plug-by communicator. If not connected then the control
unit will not be able to recognise any line fail signal from the communicator.
Line Fail Response
The exact response depends on whether the system is set or unset, as follows:
Audible
Note: Eaton's Security Business recommends audible response for line fault.
Silent
Page 126
comprises four groups of digits. Each group is three digits long, and
is separated from the next group by a "dot", for example
"192.168.000.001". Press "*" to key in the dot.
This option also presents another two sub-options where you can
key in the port numbers that Downloader "listens" to on the remote
PC for the primary and secondary IP addresses.
If the system is unset then the system logs the event. The
keypads produce a short audible tone every minute. Entering a
valid access code silences the sounders and the display
indicates a telephone line fault. The system can be set again
with the line fault present.
If the system is set then the control unit logs the event but does
not give any tone or display. The control unit cancels any
programmed siren delay if the line is out of order when an alarm
occurs.
If the system is unset then the display indicates a telephone line
fault and the control unit logs the event. The system may be set
again with the line fault present.
If the system is set then the control unit does not give any
indication or tone but does log the event. The control unit
i-on Range