Eaton i-on series Engineering Manual page 5

Hide thumbs Also See for i-on series:
Table of Contents

Advertisement

i-on Range
Partitions/Setting Options Menu:
1. Exit mode for Partition 2 and higher now defaults to "As Partition 1."
Outputs Menu:
1. There is a new "pulsed" option available for outputs that previously did not have a
pulsed option.
2. Some output types previously available on the i-onEX range are now also available for
the i-on16.
3. Outputs connected to the control unit are now shown as "Panel>OPn" on the keypad,
where "n" is the number of the output.
System Options Menu:
1. There are new options for the radio keypad so that it can be configured to unset only
the partition(s) that have an entry timer running.
2. Mains Fail Delay has changed in operation.
Communications Menu:
1. Version 4.04 now supports Downloader over IP for all control units with an Ethernet
socket.
2. There is a new version of the SIA: EX SIA3 version 2. This option is designed to help
with some ARCs receiving unwanted "Mains Fail" signals.
3. There is now an additional Line Fail Response option available for the plug-by line fail
input.
4. The SMS over PSTN option now has the ETSI Protocol 1. (Not available on i-on16.)
5. Answer on one ring has a new option to accept three rings.
6. There is a new standalone virtual keypad called Virtual Keypad Instant (VKP Instant).
This can be enabled to allow user access.
Log Menu:
1. It is now possible to look through either the Mandatory Events for EN50131, or the
Non-Mandatory Events on their own. Alternatively you can still look through the whole
Log as one list.
Page v

Advertisement

Table of Contents
loading