Fuji Xerox Versant 80 Press User Manual page 690

Table of Contents

Advertisement

21 Maintenance
2
Load the printed calibration chart on the
document feeder and select [Scan].
Note
3
Select [Start]. Auto Alignment Adjustment starts.
4
After finishing Auto Alignment Adjustment, the
tray setting screen is displayed. Select a tray to
assign the alignment adjustment settings.
For information on how to assign alignment adjustment
settings, refer to "Alignment Adjustment Setup" (P.692).
Scanning an Alignment Calibration Chart with Document Glass
The following describes how to scan a calibration chart using the document feeder and to
assign the adjustment settings to tray.
21
1
Select [Scan Chart with Document Glass] on
the [Auto Alignment Adjustment] screen.
2
Place a background sheet on the calibration
chart, and then close the document cover, and
select [Scan].
Note
690
• Once starting scanning the calibration chart,
the machine deletes the data that scanned
before. Thus do not scan a chart in different
size after you have printed as many
calibration charts as the tray.
• For the background sheet, use the file
"SIQA_sheet1_11x17.pdf" or
"SIQA_sheet1_A3.pdf" that is stored in the
[Alignment Background Sheet] folder on the
Software/Manual CD-ROM. Output the file
with 2-sided printing.
• Scan the top and bottom portions separately
for each of the front and back sides of the
calibration chart, four times in total. The
data, which is scanned at the top and
bottom portions of each of the front and
back sides of a calibration chart (four
locations in total), is used as the 1-time
measurement data.
- Vertical position: Adjust the position of a
calibration chart so that the top line
a calibration chart overlaps the bottom
line of a background sheet.
of

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents