Kodescriptplus Fatal Errors - SATO LP 100R Operator's Manual

Hide thumbs Also See for LP 100R:
Table of Contents

Advertisement

LP 100R Laser Printer Operator's Guide

KodescriptPlus Fatal Errors

Code
Description
81
Invalid Format command.
82
Column Print command.
83
Repeat command should
follow.
84
Invalid tag/label length.
86
Controller memory.
87
Invalid data has been
specified for a customized
text field.
88
Invalid data has been
detected in a specified bar
code type.
Rev: 1
Explanation
The data includes an invalid Format command.
The Column Print command (^Cnn^-) should be
used in conjunction with the Horizontal Spread
command (^Snniip^-).
No Repeat command (^Rnnnnnn^-) follows the
Buffer Store Variable Data command (^]).
The Tag/Label length specified for the document
exceeds the current form height setting for the
printer.
The METO-Logic Controller does not contain
sufficient memory for the function requested.
The customized data to be printed in a text field
does not pass the validation check required by the
user-specified format type.
The bar code to be printed does not pass the
validation check required by the user-specified bar
code type.
Page 5-30
of 30 pages
Chapter 5: Problem Solving
April, 2014