KodescriptPlus Warnings (cont'd)
Code
Description
31
Incorrect bar code data
length
32
Specified value not in
range
33
Horizontal Spread not
terminated
34
Column value exceeded
range
35
Invalid KodescriptPlus
Data Terminator
command
36
Data Terminator
command – illegal
character
37
Sectional Increment/
Decrement command
(IDSaCb±c) error
38
An unknown format
type has been coded
39
Incorrect/Unknown
multi-functional bar
code command error
Rev: 1
Explanation
The number of characters to be encoded in the bar
code exceeds the maximum number of characters
permitted for that bar code.
The command includes a value outside the valid range
of values for the command.
The Buffer Store Variable Data command (^]), which
must be used in conjunction with the Horizontal Spread
command (^Snniip^-), was not detected.
While using the (^Cnn^-) command, the
KodescriptPlus document includes a column number
that exceeds the maximum number of columns
permitted for the document.
The command includes a Data Terminator command
other than (^FF^-), (^Fn^-), (^FR^-), (^G^-), or
(^Rnnnnnn^-).
The Data Terminator command includes a character
other than a white (transparent) character or a control
character.
Either an illegal parameter value has been detected or
the maximum number of 5 incremental/decremental
sections has been exceeded.
The format type specified by the Modify Data command
(^Mdaa) cannot be found in the list of format types
available.
The "S" parameter of the (^Mbaa) (Hbbb) (Wccc)
(Od) (Re) (Nf) (Fg) (Ihi) (Ej) (Ck1) (Bm) (S)
either contains an unsupported bar code type or is
incorrectly formatted.