Kodescriptplus Errors - SATO LP 100R Operator's Manual

Hide thumbs Also See for LP 100R:
Table of Contents

Advertisement

LP 100R Laser Printer Operator's Guide

KodescriptPlus Errors

Code
Description
51
Excessive number of fields
52
Excessive number of Hard
Data fields
53
Excessive number of Line
fields
54
Excessive number of
Reverse Image fields
55
Excessive number of link
fields within a field
56
Undetermined link field
Hard Data length
57
Cannot open file for reading
58
Cannot open file for writing
59
Unable to write to file
60
Distorted PCX file
61
Number of defined fields
greater than supplied data
62
Defined fields less than
supplied data
63
Command/data not
correctly terminated
64
Invalid Field Number
character
65
Invalid Repeat Count
66
Data Condensing error
Rev: 1
Explanation
The number of defined fields exceeds the maximum
number permitted (499).
The number of defined Hard Data fields exceeds the
maximum number permitted (99).
The number of Line fields exceeds the maximum
number permitted (99).
The number of Reverse Image fields exceeds the
maximum number permitted (49).
The number of fields being linked within a field
exceeds the maximum number permitted (5).
The terminating Hard Data Delimiter was not
detected, which means that the length cannot be
determined.
Occurs when a PCX file is specified in a
KodescriptPlus file but is not found in the controller.
An error has occurred while writing a PCX file to the
controller. This file will be corrupted.
The file created by the program is corrupted.
The PCX file is corrupt. One possible cause is the
use of a color PCX file.
The number of fields coded as part of the
KodescriptPlus program is greater than the number
of data fields to be printed.
The amount of data supplied exceeds the number
of fields coded as part of the KodescriptPlus
program.
The buffer does not contain an appropriate
terminating character.
The Field Number includes an invalid character.
The Repeat Count includes an invalid character.
The number of characters to be printed in a field
that is associated with the Data Condensing On
command (^f01^-) exceeds the number of
characters specified for that field.
Page 5-28
of 30 pages
Chapter 5: Problem Solving
Continued on next page
April, 2014

Advertisement

Table of Contents
loading