Power Requirements
200-240 AC volts
30 Amps
50/60 Hz
Single phase
Termination
The United States requires a NEMA L6-30R (Twist Lock).
-
Other countries should replace the line cord at the Connector Panel Input
-
Power Supply to match the electrical codes of that country.
Power Source
The power source should not exceed the voltage/frequency fluctuations as
indicated below:
Voltage fluctuations – 200 to 240 VAC ± 10%
Frequency fluctuation – 50/60 Hz ± 3%
Temperature/Relative Humidity
The following environment is required for consistent printer performance:
Temperature – 50°–95°F (10°–35°C) with a temperature variation not
exceeding 18°F (10°C)
Relative humidity – 35% to 80% with a humidity variation not exceeding
20% to RH per hour