Table 25: Details of the 2500 W AC and 5000 W AC Power Supplies
Details
Model number
Field-replaceable unit (FRU) type
Power supply weight
Minimum installed in chassis
Maximum installed in chassis
Power supply slots
AC appliance Inlet
NOTE:
Each AC appliance
inlet requires a dedicated AC
power feed.
Enable switch
Fans
Airflow
Copyright © 2014, Juniper Networks, Inc.
Figure 20: 5000 W AC Power Supply
Power supply
LEDS
Captive
Captive
screw
screw
Enable
switch
Handle
AC Appliance
AC Appliance
inlet 1
inlet 2
Table 25 on page 39
lists the details of the 2500 W AC and 5000 W AC power supplies
used in EX6200 switches.
2500 AC Power Supply
EX6200-PWR-AC2500
Hot-insertable and hot-removable
7 lb (3.2 kg)
1
4
Install in power supply slots labeled
PSU 0
right, located at chassis front
bottom.
Number
1
Type
IEC-320-C20
Rating
16 A
1
Internal
Front-to-back
through
from left to
PSU 3
Chapter 2: Component Descriptions
5000 AC Power Supply
EX6200-PWR-AC5000
Hot-insertable and hot-removable
10 lb (4.5 kg)
1
4
Install in power supply slots labeled
through
from left to
PSU 0
PSU 3
right, located at chassis front
bottom.
2 (Labeled
and
)
Input 1
Input 2
IEC-320-C20
16 A
1
Internal
Front-to-back
39