Complete Hardware Guide for EX6210 Ethernet Switches
Slot Numbering for the Power Supply Slots
14
Figure 4: Slot Numbering for an EX6210 Switch
Line cards only
(slots 0-3)
SRE modules
or line cards
(slots 4-5)
Line cards only
(slots 6-9)
NOTE:
We recommend that you install two SRE modules for redundancy. If
you install only one SRE module, we recommend that you install it in slot 4.
See
"Installing an SRE Module in an EX6210 Switch" on page
Table 9 on page 14
lists the slot numbers for the power supplies in an EX6210 switch.
CAUTION:
Mixing different types (AC and DC or AC power supplies of different
wattage) of power supplies in the same chassis is not supported.
Mixing low-voltage input line and high-voltage input line power feeds in the
same chassis is not supported.
Table 9: Slot Numbering for Power Supply Slots on an EX6210 Switch
Chassis Front
Slot Label
Components Accepted in Slot
PSU 0
Power supply
Slot numbers 0-9
0
1
2
3
4
5
6
7
8
9
156.