Complete Hardware Guide for EX6210 Ethernet Switches
196
To connect and configure the switch by using the J-Web interface:
Transition the switch into initial setup mode:
1.
EX2200 and EX2200-C switch—Press the mode button located on the lower right
corner of the front panel for 10 seconds.
EX3200, EX3300, EX4200, EX4300, EX4500, EX4550, EX6200, or EX8200
switch—Use the
Menu
Figure 75 on page
196):
Figure 75: LCD Panel in an EX3200, EX4200, EX4300, EX4500, EX4550,
or EX8200 Switch
Press the
Menu
button until you see
1.
button.
Press
until you see
Menu
2.
If EZSetup does not appear as an option in the menu, select
return the switch to the factory default configuration. EZSetup is displayed in
the menu of standalone switches only when a switch is set to the factory default
configuration.
Press
to confirm setup and continue with EZSetup.
Enter
3.
Connect the Ethernet cable from the Ethernet port on the PC to the switch.
2.
EX2200, EX3200, or EX4200 switch—Connect the cable to port 0 (ge-0/0/0) on
the front panel of the switch.
EX3300, EX4500, or EX4550 switch—Connect the cable to the port labeled
on the front panel of the switch.
EX4300 switch—Connect the cable to the port labeled
the switch.
EX6200 switch—Connect the cable to one of the ports labeled
Fabric and Routing Engine (SRE) module in slot 4 or 5 in an EX6210 switch.
EX8200 switch—Connect the cable to the port labeled
and Routing Engine (SRE) module in slot SRE0 in an EX8208 switch or on the
Routing Engine (RE) module in slot RE0 in an EX8216 switch.
These ports are configured as the DHCP server with the default IP address, 192.168.1.1.
The switch can assign an IP address to the management PC in the IP address range
192.168.1.2 through 192.168.1.253.
From the PC, open a Web browser, type http://192.168.1.1 in the address field, and
3.
press
.
Enter
and
buttons located to the right of the LCD panel (see
Enter
MAINTENANCE MENU
. Then press
ENTER EZSetup
. Then press the
.
Enter
Factory Default
MGMT
on the rear panel of
on the Switch
MGMT
on the Switch Fabric
MGMT
Copyright © 2014, Juniper Networks, Inc.
Enter
to
MGMT

Advertisement

Table of Contents
loading

Table of Contents