Cooling System and Airflow in an EX6210 Switch
54
NOTE:
If the
INPUT OK
cords are not installed properly or the power supply has failed.
If the
INPUT OK
is not installed properly or the power supply has an internal failure.
If the
LED is lit, the power supply has failed and must be replaced.
FAIL
Connecting DC Power to an EX6200 Switch on page 180
The cooling system in an EX6210 switch consists of a single fan tray. The fan tray is a
hot-insertable and hot-removable field-replaceable unit (FRU). The fan tray contains
six fans, three rows of two fans each.
The fan tray installs vertically on the right side on the rear of the chassis and provides
front-to-back chassis cooling. Two handles, one handle on the top and one on the bottom
of the front faceplate facilitates handling of the fan tray. See
Figure 28: Fan Tray for an EX6210 Switch
Captive screws
Top
handle
Bottom
handle
Captive screws
LED and the
OUTPUT OK
LED is lit green and the
OUT OK
LED are unlit, the power
LED is unlit, the power supply
Figure 28 on page