9-1 Parameter Tables
Pn
Parameter name
No.
Origin Return
204
Final Distance
9
Electronic Gear
205
Ratio 1
(Numerator)
Electronic Gear
206
Ratio 2
(Denominator)
207
Reserved
208
Reserved
Deviation
209
Counter
Overflow Level
20A
to
Reserved
21F
9-19
Set-
Description
ting
Sets the distance from the latch signal input
position to the origin when performing origin
return.
The operation after detecting the latch signal
input position will be determined by the origin
return direction and this parameter as follows.
Origin
Sign
return
Positive
direction
Moves in the
Positive
positive
direction
direction and
*1
stops
Moves in the
Negative
negative
direction
direction and
*1
stops
*1. Reverses after decelerating to a stop if
the final distance for origin return is short
in comparison to the deceleration
distance.
Sets the numerator for the electronic gear ra-
tio.
Setting this parameter to 0 automatically sets
the encoder resolution as the numerator.
(131072 for a 17-bit absolute encoder, or
10000 for a 2,500-p/r incremental encoder).
Note Set the electronic gear ratio within the
range of 1/100 to 100 times. A
parameter setting alarm (alarm code
93) will occur if the ratio is set outside
of this range.
Sets the denominator for the electronic gear
ratio.
Note Set the electronic gear ratio within the
range of 1/100 to 100 times. A
parameter setting alarm (alarm code
93) will occur if the ratio is set outside
of this range.
Do not change.
Do not change.
Sets the deviation counter overflow level.
The value will become saturated at
27
134217728 (= 2
) pulse after multiplying with
the electronic gear ratio.
Setting this parameter to 0 will disable
deviation counter overflow.
Do not change.
Default
Setting
Negative
Decelerates to a
stop, reverses,
then moves in
the negative
100
direction and
stops
Decelerates to a
stop, reverses,
then moves in
the positive
direction and
stops
1
1
0
0
20000
---
Set val-
Unit
Setting Range
−1073741823
Com-
mand
to
B
units
1073741823
---
0 to 131072
C
---
1 to 65535
C
---
---
---
---
---
---
Com-
0 to
mand
A
2147483647