Omron OMNUC G User Manual page 223

Ac servomotors/servo drives with built-in mechatrolink-ii communications
Table of Contents

Advertisement

Noise Filters for Servomotor Output
Use noise filters without built-in capacitors on the Servomotor output lines.
Select a noise filter with a rated current at least two times the Servo Drive's continuous output
current.
The following table shows the noise filters that are recommended for Servomotor output.
Manufacturer
3G3AX-NF001
3G3AX-NF002
3G3AX-NF003
OMRON
3G3AX-NF004
3G3AX-NF005
3G3AX-NF006
Note 1. Servomotor output lines cannot use the same noise filters for power supplies.
Note 2. Typical general-purpose noise filters are made for power supply frequencies of 50/60 Hz. If
these noise filters are connected to the PWM output of the Servo Drive, a very large (about
100 times larger) leakage current will flow through the noise filter's condenser and the Servo
Drive could be damaged.
Dimensions
3G3AX-NF001/-NF002
C
B
A
P
Model
3G3AX-NF001
140
3G3AX-NF002
160
4-3 Wiring Conforming to EMC Directives
Rated
Model
current
6 A
12 A
25 A
50 A
75 A
100 A
Four, M
J
M4
H
Dimensions (mm)
A
B
C
E
125
110
70
95
145
130
80
110
Remarks
For inverter output
F
G
H
J
22
50
20
4.5 dia.
30
70
25
5.5 dia.
M
P
156
176
4-42
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents