R88D-GN75H-ML2
If an External Regeneration Resistor is necessary, connect it between B1 and B2 as shown in the
diagram below.
Servo Drive
B1
B2
Precautions
for Correct Use
4-4 Regenerative Energy Absorption
θ>
Thermal Switch Output
External
Regeneration
Resistor
Connect the thermal switch output so that the main circuit power supply is
shut OFF when the contacts open.
When using multiple External Regeneration Resistors, connect each
thermal switch in series.
The resistor may be damaged by burning, or cause fire if it is used without
setting up a power supply shutoff sequence using the output from the
thermal switch.
4