Pn
Set-
Parameter name
No.
ting
Sets the deceleration for positioning operations.
A setting of "0" is regarded as "1".
Linear
The setting will be handled after conversion to
10A
Deceleration
an unsigned 16-bit data (0 to 65535).
Constant
Example: −32768
10B
Reserved
Do not change.
10C
Reserved
Do not change.
10D
Reserved
Do not change.
Moving
Sets the moving average time for position
10E
Average Time
commands.
Sets the direction for origin return.
Origin Return
10F
0
Mode Settings
1
Sets the operating speed for origin return, from
Origin Return
when the origin proximity signal is turned ON, to
110
Approach Speed
when it is turned OFF and the latch signal is
1
detected.
Origin Return
Sets the operating speed for origin return, from
111
Approach Speed
when the latch signal is detected, to when the
2
Origin Return Final Distance (Pn204) is reached.
Explanation
8000h = 32768
−1
FFFFh = 65535
Positive direction
Negative direction
9-1 Parameter Tables
Default
Setting
Unit
Setting
Range
×
10000
−32768 to
[Com-
100
mand
32767
units/
2
s
]
0
---
---
0
---
---
0
---
---
×
0.1
0
0 to 5100
ms
0
---
0 to 1
×
100
[Com-
50
mand
1 to 32767
units/
s]
×
100
[Com-
5
mand
1 to 32767
units/
s]
Set
value
B
---
---
---
B
B
B
B
9
9-16

Hide quick links:

Advertisement

Table of Contents
loading