3-2 Servomotor Specifications
*1. These are the values when the Servomotor is combined with a Servo Drive at room temperature (20°C, 65%).
The maximum momentary torque indicates the standard value.
*2. Applicable Load Inertia
The operable load inertia ratio (load inertia/rotor inertia) depends on the mechanical configuration and
its rigidity. For a machine with high rigidity, operation is possible even with high load inertia. Select an
appropriate motor and confirm that operation is possible.
If the dynamic brake is activated frequently with high load inertia, the dynamic brake resistor may
burn. Do not repeatedly turn the Servomotor ON and OFF while the dynamic brake is enabled.
*3. The allowable radial and thrust loads are the values determined for a service life of 20,000 hours at normal
3
operating temperatures.
The allowable radial loads are applied as shown in the following diagram.
*4. This is an OFF brake. (It is reset when excitation voltage is applied).
*5. The operation time is the value (reference value) measured with a surge suppressor (CR50500 manufac-
tured by Okaya Electric Industries Co., Ltd.).
Torque-Rotational Speed Characteristics for 2,000-r/min Servomotors
2,000-r/min Servomotors with 200-VAC Power Input
The following graphs show the characteristics with a 3-m standard cable and a 200-VAC input.
R88M-G1K020T (1 kW)
(N·m)
13.5
15
10
Repetitive usage
4.8
5
Continuous usage
0
1000
R88M-G3K020T (3 kW)
(N·m)
50
41.2
Repetitive usage
25
14.3
Continuous usage
0
1000
R88M-G7K515T (7.5 kW)
(N·m)
111
100
Repetitive usage
50
48
Continuous usage
0
1000
3-27
Radial load
Thrust load
Center of shaft (LR/2)
R88M-G1K520T (1.5 kW)
(N·m)
18.5
13.5 (2200)
20
10
7.15
5.5
4.8
3.2
(r/min)
2000
3000
0
R88M-G4K020T (4 kW)
(N·m)
41.2 (2200)
14.3
14.3
9.5
2000
3000
(r/min)
111
100
48
36
(r/min)
1500
2000
18.5 (2200)
Repetitive usage
14.3
7.15
4.7
Continuous usage
(r/min)
1000
2000
3000
54.9 (2000)
Repetitive usage
Continuous usage
(r/min)
R88M-G2K020T (2 kW)
(N·m)
26.5
26.5 (2200)
30
Repetitive usage
15
9.54
9.54
Continuous usage
0
1000
2000
3000
R88M-G5K020T (5 kW)
(N·m)
70.6
70.6 (2000)
70
Repetitive usage
35
23.8
23.8
Continuous usage
0
1000
2000
3000
13.2
6.3
(r/min)
23.0
15.8
(r/min)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents