4.3 The Drive and Programming Modes

◆ Changing Parameter Settings or Values

This example explains changing C1-02 (Deceleration Ramp 1) from 1.50 seconds (default) to 2.50 seconds.
1.
Turn on the power to the drive. The initial display appears.
2.
Press
or
until the Parameter Setting Mode screen appears.
3.
Press
to enter the parameter menu tree.
4.
Press
or
to select the C parameter group.
5.
Press
two times.
6.
Press
or
to select the parameter C1-02.
7.
Press
to view the current setting value (1.5 s). The left most digit flashes.
8.
Press
F1
,
F2
or
left
right
9.
Press
and enter 0020.0.
10.
Press
to confirm the change.
92
Step
until the desired number is selected. "1" flashes.
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Display/Result
- MODE -
DRV
Rdy
Speed Ref (OPR)
U1-01= 0.00%
U1-02= 0.00%
RSEQ
U1-03= 0.00A
LREF
FWD
- MODE -
PRG
Programming
HELP
FWD
DATA
-PRMSET-
PRG
Initialization
A1-00=
0
Select Language
FWD
-PRMSET-
PRG
Basic Setup
C1-01 =
1.50 sec
Accel Ramp 1
FWD
-PRMSET-
PRG
-PRMSET-
Accel/Decel
Accel Ramp 1
C1-01=
1.50 sec
C1-01=
1.50 sec
(0.0~600.00)
Accel Ramp 1
"1.50 sec"
FWD
FWD
-PRMSET-
PRG
Decel Ramp 1
C1-02=
1.50 sec
(0.0~600.00)
"1.50 sec"
FWD
-PRMSET-
PRG
Decel Ramp 1
C1-02= 001.50 sec
(0.0~600.00)
"1.50 sec"
FWD
-PRMSET-
PRG
Decel Ramp 1
C1-02=001.50 sec
(0.0~600.00)
"1.50 sec"
FWD
-PRMSET-
PRG
Decel Ramp 1
C1-02=002.50 sec
(0.0~600.00)
"1.50 sec"
FWD
Entry Accepted