B.10 o: Operator-Related Settings
B.10 o: Operator-Related Settings
The o parameters set up the digital operator displays.
u

o1: Digital Operator Display Selection

No.
(Addr.
Name
Hex)
o1-01
Drive Mode Unit
(0500)
Monitor Selection
o1-02
User Monitor Selection
(0501)
after Power Up
o1-03
Digital Operator Display
(0502)
Selection
o1-04
V/f Pattern Display Unit
(0503)
o1-05
(0504)
LCD Contrast Control
<2>
o1-10
User-Set Display Units
(0520)
Maximum Value
o1-11
User-Set Display Units
(0521)
Decimal Display
<1> Default setting is determined by parameter A1-02, Control Method Selection.
<2> Available in drive software versions PRG: 1019 and later.
<3> Default setting is determined by parameter o1-03, Digital Operator Display Selection.
u

o2: Digital Operator Keypad Functions

No.
(Addr.
Name
Hex)
o2-01
LO/RE Key Function
(0505)
Selection
o2-02
STOP Key Function
(0506)
Selection
o2-03
User Parameter Default
(0507)
Value
312
LCD Display
Switches the display after the power has been turned on.
When using an LED operator, pressing the up arrow key will
display the following data: frequency reference → rotational
direction → output frequency → output current → output
User Monitor Sel
voltage → U1-oo.
Note:
Selects the information displayed on the digital operator when
Power-On Monitor
the power is turned on.
1: Frequency Ref
1: Frequency reference (U1-01)
2: FWD/REV
2: Direction
3: Output Freq
3: Output frequency (U1-02)
4: Output Current
4: Output current (U1-03)
5: User Monitor
5: User-selected monitor (set by o1-01)
Sets the units the drive should use to display the frequency
Display Unit Sel
reference and motor speed monitors.
0: 0.01 Hz
0: 0.01 Hz
1: 0.01 %
1: 0.01% (100% = E1-04)
2: r/min
2: r/min (calculated using the number of motor poles setting in
3: User Units
E2-04, E4-04, or E5-04)
3: User-selected units (set by o1-10 and o1-11)
V/f Ptrn Unit
0: Hz
0: Hertz
1: r/min
1: RPM
Sets the contrast of the LCD operator.
LCD Contrast
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output
UserDisp Scaling
frequency.
o1-11 sets the position of the decimal position.
UserDisp Dec Sel
LCD Display
LO/RE Key
0: Disabled
0: Disabled
1: Enabled. LO/RE key switches between LOCAL and
1: Enabled
REMOTE operation.
Oper STOP Key
0: Disabled. STOP key is disabled in REMOTE operation.
0: Disabled
1: Enabled. STOP key is always enabled.
1: Enabled
0: No change.
User Default Sel
1: Set defaults. Saves parameter settings as default values for
0: No Change
a User Initialization.
1: Save User Init
2: Clear all. Clears the default settings that have been saved for
2: Clear User Init
a User Initialization.
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
Description
Enter the "1-oo" portion of "U1-oo" to view
the monitor. Certain monitors are not available
in all control modes.
Description
Values
Page
Default: 106
(Monitor U1-06)
Range: 104 to
813
Default: 1
Range: 1 to 5
<1>
Default:
Range: 0 to 3
<1>
Default:
Range: 0, 1
Default: 3
Min.: 0
Max.: 5
<3>
Default:
Range: 1 to
60000
<3>
Default:
Range: 0 to 3
Values
Page
Default: 1
Range: 0, 1
Default: 1
Range: 0, 1
Default: 0
Range: 0 to 2