Perform Engine Maintenance - Perkins Models - Genie S-40 Service Manual

Serial number range from s40-7001 to s4012-17231
Hide thumbs Also See for S-40:
Table of Contents

Advertisement

Section 3 • Scheduled Maintenance Procedures
CHECKLIST A PROCEDURES
A-9
Perform Engine Maintenance -
Perkins Models
Engine specifications require that this procedure be
performed every 50 hours.
Proper engine maintenance, following the engine
manufacturer's maintenance schedule, is essential
to good engine performance and service life.
Failure to perform the maintenance procedures
can lead to poor engine performance and
component damage.
Perkins models
Required maintenance procedures and additional
engine information are available in the
Perkins 404-22 Operation Manual
(Perkins part number TPD 1443S).
Perkins 404-22 Operation Manual
Genie part number
To access the engine:
Remove the engine tray retaining fasteners
located under the engine tray. Loosen the pivot
fastener located at the platform end of the
engine tray. Swing the engine tray out and
away from the machine and secure it from
moving.
Crushing hazard. Failure to secure
the engine pivot plate from moving
could result in death or serious
injury.
3 - 12
A-10
Inspect the Fuel Filter/Water
Separator - Deutz Models
Genie specifications require that this procedure be
performed every 100 hours or monthly, whichever
comes first.
Proper maintenance of the fuel filter/water
separator is essential for good engine
performance. Failure to perform this procedure can
lead to poor engine performance and/or hard
starting, and continued use may result in
component damge. Extremely dirty conditions may
require this procedure be performed more often.
94890
Note: Perform this procedure with the engine off.
1 Loosen the drain plug located at the bottom of
the filter. Allow the water to drain into a suitable
container until fuel starts to come out.
Immediately tighten the drain plug.
S-40 • S-45
October 2013
Explosion and fire hazard. Engine
fuels are combustible. Perform this
procedure in an open, well-
ventilated area away from heaters,
sparks, flames and lighted
tobacco. Always have an
approved fire extinguisher within
easy reach.
Part No. 102521