Preparing Corotron Replacement - Oce VarioStream 8000 User Manual

Continuous printing system
Hide thumbs Also See for VarioStream 8000:
Table of Contents

Advertisement

Preparing corotron replacement

Attention:
Before replacing the corotrons, please observe the safety directives in the section
Replacing the corotrons - overview on page
This section only applies if the message 'Replace corotrons' is displayed. All
corotrons must be replaced.
Note:
A different procedure applies when replacing a torn corotron wire (see
charge corotron on page 364
To prepare for corotron replacement
[196]
Proceed as follows:
1.
If the printing system has not yet stopped, click the 'Stop' button.
2.
On the operator panel, select the 'Replace consumables' -> 'Replace coro-
trons' menu.
3.
Click the 'OK' button to start the corotron replacement process.
Information on the icons displayed on the operator panel under 'Steps': See
Explanation of icons on page
4.
Click the 'OK' button to move the corotrons to the test position.
5.
Open the cover and both doors at the front of the printing system.
6.
Remove charge corotrons on page 362
360.
or
Remove torn discharge corotron on page
118.

Preparing corotron replacement

Remove torn
368).
361

Advertisement

Table of Contents
loading

Table of Contents